Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
800b010a-1e81xxxx
800b010a-1e82xxxx
800b010a-1e83xxxx
800b010a-1e84xxxx
800b010a-1e85xxxx
800b010a-1e86xxxx
Redundancy Cooling Zone 1 has been
reduced.
Error
Redundancy has
been lost and is
insufficient to
continue operation.
1.
Make sure that the
connectors on fans 1
and 2 are not damaged.
2.
Make sure that the fan 1
and 2 connectors on the
system board are not
damaged.
3.
Make sure that the fans
are correctly installed.
4.
Reseat the fans.
5.
Replace the fans.
Sensor RAID Error has transitioned to
critical from a less severe state.
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Check the hard disk
drive amber status
LEDs to identify the
failed hard disk drive or
check the RAID
controller system
management software
event logs.
2.
Reseat the hard disk
drive for which the
status LED is lit.
3.
Replace the defective
hard disk drive.
800b010c-2581xxxx
Redundancy Bckup Mem Status has
been reduced.
Error
Redundancy has
been lost and is
insufficient to
continue operation.
1.
Check the system-event
log for DIMM failure
events (uncorrectable or
PFA) and correct the
failures.
2.
Re-enable mirroring in
System Settings
in the
Setup utility (see “Using
the Setup utility” on
page 402 for more
information).
800b0208-1381xxxx
Redundancy Degraded for Power Unit
has asserted.
Warning
Redundancy
degraded has
asserted.
Check the power supply to
make sure that the power is
connected correctly.
800b0308-1381xxxx
Non-redundant:Sufficient Resources
from Redundancy Degraded or Fully
Redundant for
[RedundancySetElementName] has
asserted
Info
Redundancy set has
transitioned from
redundancy
degraded or fully
redundant to
non-
redundant:sufficient.
The power supplies are
non-redundant.
800b050a-1e81xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Error
Cooling zone alert.
Cooling zone 1 error:
Replace fan 1.
800b050a-1e82xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Error
Cooling zone alert.
Cooling zone 2 error:
Replace fan 2.
Chapter 3. Diagnostics
185
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...