Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f030c-0781xxxx
Scrub Failure for "Planar DIMMs" on
subsystem "System Memory"
Error
A Memory Scrub
failure has been
detected.
1.
Check IBM support site
for an applicable
RETAIN tip or firmware
update that applies to
this memory error.
2.
Swap the affected
DIMM with a DIMM of
the same size and type
from a different
memory channel.
3.
Run the Setup utility to
enable all the DIMMs.
4.
If the DIMM still fails
on a different memory
channel, replace the
DIMM.
5.
If the swapped DIMM
fails on the original
DIMM connector,
inspect the DIMM
connector for debris or
damage. If the
connector is damaged,
(trained technician only)
replace the system
board.
806f030c-2581xxxx
Scrub Failure All DIMMs on
subsystem System Memory
Error
A Memory Scrub
failure has been
detected.
1.
Check IBM support site
for an applicable
RETAIN tip or firmware
update that applies to
this memory error.
2.
Swap the affected
DIMM with a DIMM of
the same size and type
from a different
memory channel.
3.
Run the Setup utility to
enable all the DIMMs.
4.
If the DIMM still fails
on a different memory
channel, replace the
DIMM.
5.
If the swapped DIMM
fails on the original
DIMM connector,
inspect the DIMM
connector for debris or
damage. If the
connector is damaged,
(trained technician only)
replace the system
board.
202
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...