Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
Message
Severity
Description
Action
80010b01-1881xxxx
Numeric sensor MEU
Chipset Temp going high
(upper non-recoverable) has
asserted.
Error
MAX5 chipset
temperature
Overspec.
1.
Make sure that
the ambient
temperature is
within the
product
specifications for
the MAX5 and
the host server.
2.
Make sure that
the fans are
operating
properly, there
are no
obstructions to
the airflow, the
air baffles are
installed correctly,
and the server
cover is installed
and completely
closed (see
“Replacing the
server top cover”
on page 265).
3.
(Trained service
technician) Make
sure that all heat
sinks are properly
installed on the
host server.
8003010c-1881xxxx
Sensor Lane FailoverMEU
has asserted
Info
A memory lane
failover event has
occurred.
No action;
information only.
806f070c-1881xxxx
Configuration error for
Memory Device
n
in
Memory Expansion Unit 1
on subsystem System
Memory has deasserted
Info
MAX5 memory
expansion module
configuration error
deasserted.
No action;
information only.
Memory Logging Limit
removed for Memory Device
n
in Memory Expansion Unit
1 on subsystem System
Memory
Info
MAX5 memory
expansion module
memory logging
limit deasserted.
No action;
information only.
Uncorrectable error recovery
detected for Memory Device
n
in Memory Expansion Unit
1 on subsystem System
Memory
Info
MAX5 memory
expansion module
memory Bank
n
error
recovered.
No action;
information only.
MEU Bank
n
Status on
subsystem System Memory
throttled
Info
MAX5 memory
expansion module
throttling asserted.
No action;
information only.
224
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...