Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
Message
Severity
Description
Action
81070608-1881xxxx
Sensor MEU PS2 12V OV
has deasserted the transition
to non-recoverable
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
No action;
information only.
80070608-1881xxxx
Sensor MEU PS2 12V OV
has transitioned to
non-recoverable
Error
MAX5 memory
expansion module
power supply 2 error
detected.
1.
Check MAX5
memory
expansion
module LEDs.
2.
Check MAX5
memory
expansion
module power
supply 2 LEDs.
3.
Replace the
MAX5 memory
expansion
module power
supply 2.
81070608-1881xxxx
Sensor MEU PS1 12V OV
has deasserted the transition
to non-recoverable
Info
MAX5 memory
expansion module
power supply 1 is
now normal.
No action;
information only.
80070608-1881xxxx
Sensor MEU PS1 12V OV
has transitioned to
non-recoverable
Error
MAX5 memory
expansion module
power supply 2 error
detected.
1.
Check MAX5
memory
expansion
module LEDs.
2.
Check MAX5
memory
expansion
module power
supply 1 LEDs.
3.
Replace the
MAX5 memory
expansion
module power
supply 1.
81070208-1881xxxx
Sensor MEU PS2 Fan has
transitioned to a less severe
state from critical
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
No action;
information only.
Chapter 3. Diagnostics
239
Содержание System x3690 X5
Страница 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 13: ...Safety statements Safety xi...
Страница 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 407: ...1 2 Chapter 5 Removing and replacing components 389...
Страница 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 453: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices 435...
Страница 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 461: ...weight of memory enclosure 28 Index 443...
Страница 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Страница 463: ......
Страница 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...