Hardware components
The device has a modular and scalable mechanical construction that allows a wide
range of flexibility in installation, fabric design, and maintenance. The device can
be mounted with the cables facing either the front or the rear of the equipment
rack, and consists of the following:
v
Up to eight slots for hot-swappable port blade assemblies, providing up to 384
32-Gbps Fibre Channel ports.
v
Two half-size slots for control processor (CP) blades:
– A single active CP blade can control all the ports in the device.
– The standby CP blade assumes control of the device if the active CP blade
fails.
v
Two slots for core routing (CR) blades:
– CR blade interconnects all port blades.
– Up to 32 4x32-Gbps QSFP (ICL) ports.
– ICL ports allow interconnection with neighboring chassis
– Both CR blades are active.
v
Up to four slots for modular, hot-swappable 34-port SX6 extension blades.
Blades provide 16 32– Gbps Fibre Channel (FC) ports supporting 8, 16, and 32
Gbps or 16 16-Gbps FC ports supporting 4, 8, and 16 Gbps; 16 GbE ports
supporting 1 or 10 Gbps; and 2 GbE ports supporting 40 Gbps. Extension blades
enable long-distance communication over an existing IP infrastructure.
v
Modular, hot-swappable field-replaceable units (FRUs):
– Three fan assemblies, available with nonport-side intake (NPI) or
nonport-side exhaust (NPE) airflow.
– Up to four power supply assemblies, available with nonport-side intake (NPI)
or nonport-side exhaust (NPE) airflow. The power supplies are approved for
100–120 VAC and 200–240 VAC.
- At 100–120 VAC (nominal): Four power supply assemblies are required for
high availability. Refer to the "Power requirements" section in the
Appendix B, “Product specifications,” on page 235 for specific high
availability–requirements.
- 200–240 VAC (nominal) is recommended for efficiency. Depending on
quantity ordered, three or four power supply assemblies are provided.
Refer to the "Power requirements" section in the Appendix B, “Product
specifications,” on page 235 for specific high-availability requirements.
- Redundant AC primary power connections ensure high availability. Each
power supply assembly has its own connector, so four is the number of
primary power connections for optimum efficiency and redundancy.
– Two World Wide Name (WWN) cards located on the nonport side of the
device behind the WWN card bezel.
– Blades use small form-factor pluggable (SFP+ and QSFP+) optical
transceivers.
- The 10-Gbps speed must be manually set and requires special 10-Gbps FC
SFP+ transceivers.
- The 32-Gbps SFP+ transceivers support speeds of 8, 16, and 32 Gbps.
- The 16-Gbps SFP+ transceivers support speeds of 4, 8, and 16 Gbps.
- The 4x32-Gbps QSFP+ transceivers on the core routing blades provide four
32–Gbps inter-chassis links (ICL) clustered in a single quad connector and
cable.
2
SAN512B-6 Installation, Service, and User Guide
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...