Note:
The device can be accessed by remote connection using any of the
available management tools, such as Telnet or Web Tools. Ensure that the
device is not modified using other connections during the rest of this
procedure.
2.
Reconnect the transceivers and cables to the port blades.
Note:
The ports and cables used in trunking groups must meet specific
requirements. For a list of these requirements, refer to the Fabric OS
Administrator's Guide.
a.
Position one of the transceivers so that the key is oriented correctly to the
port and insert the transceiver into the port until it is firmly seated and the
latching mechanism clicks.
b.
Select the cable that corresponds to the port and position it so that the key
(the ridge on one side of the cable connector) is aligned with the slot in the
transceiver. Insert the cable into the transceiver until the latching
mechanism clicks.
c.
Repeat step a and step b for the remaining ports.
d.
Organize the cables as required.
Note:
Do not route cables in front of the air exhaust vents.
What to do next
Allow the customer to “Downloading the configuration” and “Verifying correct
operation of system” on page 200 and then proceed with “Reconnecting system to
the network and fabric” on page 198.
Downloading the configuration
About this task
Once the chassis and its various components have been reassembled and powered
back on, use the
configDownload
command to restore the original configuration.
The
configDownload
command can be entered through a Telnet or serial session,
but the device must have an Ethernet connection to the server name or IP address
of the host for the download process to complete. For more information, refer to
the
help configdownload
command or the Fabric OS Command Reference.
Complete the following steps to download the configuration.
Procedure
1.
Log in to the device as admin.
switch:admin> configdownload
Protocol (scp, ftp, sftp, local) [ftp]: ftp
Server Name or IP Address [host]: 123.123.123.123
User Name [user]: Admin24
Path/Filename [<home dir>/config.txt]: config-switch.txt
Section (all|chassis|switch [all]): all
Chapter 16. Replacing the Chassis
199
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...