Procedure
1.
Enter
slotShow
. The command output shows the new CP blade as "enabled."
If the standby CP is unresponsive, you can try unplugging the new CP blade,
running
haDisable
on the active CP blade, and plugging the new CP blade
back in. At that point, you can repeat step 1 to begin the verification process
again.
2.
Log into each CP blade and enter the
haShow
command to display the CP status.
Verify the CP state, status, health, and that the HA state is synchronized.
Remedy any issues before proceeding. For more information on
haShow
output,
refer to theFabric OS Command Reference.
3.
Determine the firmware version of installed CP blades by entering
firmwareShow
. If the serial console on the replacement CP blade is connected,
issue the
firmwareShow
command there. More information is available through
the console.
4.
If the firmware versions for both CP blades are the same, skip to“Completing
the replacement” on page 143.
If the firmware version on the replacement (standby) blade does not match that
on the active CP blade, a warning message appears with the results of the
firmwareshow
command.
WARNING: The local CP and remote CP have different versions
of firmware, please
5.
Bring the replacement blade firmware to the same firmware level as the active
blade using one of the following procedures:
v
Run the
firmwaresync
command on the active CP blade to copy all firmware
from the active CP blade to the standby CP blade.
Note:
Using this command requires that existing telnet, secure telnet, or SSH
sessions to the standby CP blade to be restarted.
v
Run the
firmwareDownload -s
command or
firmwaresync
command (if
versions are compatible) to update firmware on the replacement blade to
bring it up to the proper level.
6.
Perform one of the following tasks to download firmware:
v
If you are using an FTP server to download the firmware, skip to the
procedure for downloading firmware from an FTP server.
v
If you are using a USB device to download the firmware, skip to the
procedure for downloading firmware from a USB device. If the firmware on
the standby CP blade is more than one level down from the level on the
active CP blade, you must have formatted USB devices for each of the
versions you will need to upgrade.
For details on supported upgrade paths and steps to upgrade through multiple
versions of Fabric OS, refer to theFabric OS Release Notes, and theFabric OS
Upgrade Guide.
Downloading firmware from FTP server:
About this task
For this task, determine the correct sequence of upgrading firmware versions to
reach your target version.
Complete the following steps to download the firmware from an FTP server to the
replacement blade.
138
SAN512B-6 Installation, Service, and User Guide
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...