Before you begin:
Read “Safety information” on page 230.
Read the documentation that comes with the
drive.
If the server has a RAID adapter installed, review
the information provided with the RAID adapter
for information about the RAID adapter and
disk-array configuration.
Prepare the drive for installation (see
“Preinstallation steps (all bays)” on page 127).
Refer to the following illustration of the tower model while
you perform the steps in this procedure.
.3/
Drive
.4/
Drive tray handle (in open position)
To replace a drive in a hot-swap bay:
1. If the server is a tower model, unlock and open the
server door (see “Preparing to install options” on
page 100).
Attention
To maintain proper system cooling, do not
operate the server for more than two minutes
without either a drive or a filler panel installed for
each bay.
2. Remove the defective hard disk drive
.3/
by placing
the handle
.4/
on the drive to the open position
(perpendicular to the drive) and pulling the hot-swap
tray from the bay.
Netfinity 5600 - Type 8664
133
Содержание 866441Y - Netfinity 5600 - 8664
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 168: ...7 To complete the installation refer to the documentation that comes with the rack enclosure 160 Netfinity Server HMM...
Страница 244: ...236 Netfinity Server HMM...
Страница 245: ...Related service information 237...
Страница 246: ...238 Netfinity Server HMM...
Страница 247: ...Related service information 239...
Страница 258: ...250 Netfinity Server HMM...
Страница 259: ...Related service information 251...
Страница 275: ......
Страница 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...