a. Insert the left bracket tab into the slot
.2/
in the
left side of the server until the upper notch
.1/
aligns with the side of the server.
Note
The left bracket is marked with an L.
b. Push the bracket up until the holes in the bracket
align with the holes in the side of the server.
c. Insert two M3.5 by 7-mm screws through the left
bracket into the holes on the left side of the
server; then, tighten the screws.
d. Perform steps 16a through 16c using the right
bracket and the right side of the server.
17. Install the new trim bezel from the conversion kit.
a. Align the tabs on the back of the bezel with the
tab openings on the front of the server.
184