When a power-on password is set, POST does not
complete until you enter the password. If you forget the
power-on password, you can regain access to the server
through one of the following methods:
If an administrator password has been set, enter the
administrator password at the power-on prompt. (If
necessary, see “Using the administrator password
menu” on page 32 for details.) Start the System
Configuration Utility program and change the
power-on password as previously described in this
section (see steps 1 through 5).
You can change the position of the password override
switch (switch 4 of switch block 2) to the ON position
as described in “Bypassing an unknown power-on
password” on page 53.
You can remove the battery as described in
“Replacing the battery” on page 161 and then install
the battery.
To set a power-on password:
1. Select Power-on Password from the System
Security menu; then, press Enter.
The Power-on Password menu appears.
2. Type the password in the Enter Power-on Password
data field.
You can use any combination of up to seven
characters (A–Z, a–z, and 0–9) for the power-on
password. Keep a record of the password in a
secure place.
3. Move the cursor to the Enter Power-on Password
Again data field and type the password again.
Note
A message appears if the two passwords do not
match. If this happens, press Esc to cancel the
request and return to the System Security menu.
4. If a message appears telling you to select another
password, press Enter to return to the Power-On
Password menu. Choose a different password to use
for the power-on password.
5. Select Change Power-on Password to save the new
password; then, press Enter.
To delete a power-on password:
1. Select Power-on Password from the System
Security menu; then, press Enter.
The Power-on Password menu appears.
2. Select Delete Power-on Password; then, press
Enter.
3. A confirmation window appears. Press Enter to
delete the power-on password. Press Esc to cancel
the request and return to the System Security menu.
Netfinity 5600 - Type 8664
31
Содержание 866441Y - Netfinity 5600 - 8664
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 168: ...7 To complete the installation refer to the documentation that comes with the rack enclosure 160 Netfinity Server HMM...
Страница 244: ...236 Netfinity Server HMM...
Страница 245: ...Related service information 237...
Страница 246: ...238 Netfinity Server HMM...
Страница 247: ...Related service information 239...
Страница 258: ...250 Netfinity Server HMM...
Страница 259: ...Related service information 251...
Страница 275: ......
Страница 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...