DIAGNOSTIC PROGRAMS
a. Use the cursor control keys (arrow keys) to scroll
across the menu headings.
b. Press Enter to view the selections under the
main headings.
c. Use the Up Arrow (
↑
) and Down Arrow (
↓
) keys
to scroll down to the test that you want to run,
and press Enter.
Note
If you select
Run Normal Test
or
Run Quick
Test
from the Extended test menu, omit
steps 4 and 5.
d. Select the test components that you want to run.
e. Use these keys to tailor your selection:
Space = Select a test component
F1 = Help
F2 = Options (a pop-up window appears)
F3 = Test log
F5 = Run all tests
F10 = Deselect all
Esc = Exit
Enter = Run highlighted tests
CTRL
+
Enter = Run tests in view
4. Select either Extended or Basic from the top of the
screen.
5. Select the test that you want to run from the list that
appears; then, follow the instructions on the screen.
When the tests have completed, you can view the
Test Log by selecting Utility from the top of the
screen.
Also, you can view server configuration information
(such as system configuration, memory contents,
interrupt request (IRQ) use, direct memory access
(DMA) use, device drivers, and so on) by selecting
Hardware Info from the top of the screen.
6. When you are finished running the tests or viewing
information in the Diagnostics Utility program, select
Quit from the top of the screen.
If the hardware checks out OK, but the problem persists
during normal server operations, a software error might be
the cause. If you suspect a software problem, refer to the
information that comes with the software package.
Using the Online Manual:
To obtain detailed
descriptions of the available tests, press F1 twice to gain
access to the Diagnostics Utility program
Online Manual.
The
Online Manual also describes:
The error messages that the diagnostic tests generate
The menu structure and options
The function keys
Netfinity 8500R - Type 8681
13
Содержание 8500R - Netfinity - 8681
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Страница 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Страница 240: ...Processor Housing Assembly A1 A2 A3 A4 B1 B2 B3 B4 B1 B2 B3 B4 A3 A4 A2 A1 1 2 3 4 5 6 7 8 9 232 Netfinity Server HMM...
Страница 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Страница 261: ...Related service information 253...
Страница 262: ...254 Netfinity Server HMM...
Страница 263: ...Related service information 255...
Страница 264: ...256 Netfinity Server HMM...
Страница 265: ...Related service information 257...
Страница 278: ...270 Netfinity Server HMM...
Страница 279: ...Related service information 271...
Страница 280: ...272 Netfinity Server HMM...
Страница 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...