Error Code/Symptom
FRU/Action
202-XXX-004
(Failed Cache test)
1. Processor B4
2. Processor Daughter
Board B
3. Processor Controller
Card
202-XXX-005
(Failed Cache test)
1. Processor A1
2. Processor Daughter
Board A
3. Processor Controller
Card
202-XXX-006
(Failed Cache test)
1. Processor A2
2. Processor Daughter
Board A
3. Processor Controller
Card
202-XXX-007
(Failed Cache test)
1. Processor A3
2. Processor Daughter
Board A
3. Processor Controller
Card
202-XXX-008
(Failed Cache test)
1. Processor A4
2. Processor Daughter
Board A
3. Processor Controller
Card
206-XXX-XXX
(Failed Diskette Drive test)
1. Diskette Drive Cable
2. Media power cable
3. Diskette Drive
4. I/O Function Card
215-XXX-000
(Failed CD-ROM test)
1. CD-ROM Drive Cable
2. Media power cable
3. CD-ROM drive
4. I/O Function Card
217-XXX-001
(Failed BIOS Fixed Disk
test)
1. Fixed Disk 1
217-XXX-002
(Failed BIOS Fixed Disk
test)
1. Fixed Disk 2
301-XXX-XXX
(Failed Keyboard test)
1. Keyboard
2. I/O Function Card
415-XXX-XXX
(Failed modem test)
1. Modem Card
Netfinity 8500R - Type 8681
189
Содержание 8500R - Netfinity - 8681
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Страница 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Страница 240: ...Processor Housing Assembly A1 A2 A3 A4 B1 B2 B3 B4 B1 B2 B3 B4 A3 A4 A2 A1 1 2 3 4 5 6 7 8 9 232 Netfinity Server HMM...
Страница 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Страница 261: ...Related service information 253...
Страница 262: ...254 Netfinity Server HMM...
Страница 263: ...Related service information 255...
Страница 264: ...256 Netfinity Server HMM...
Страница 265: ...Related service information 257...
Страница 278: ...270 Netfinity Server HMM...
Страница 279: ...Related service information 271...
Страница 280: ...272 Netfinity Server HMM...
Страница 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...