v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3400 M3 Types 7378 and 7379,” on page 141 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Redundancy Power Unit has been
reduced.
Error
Redundancy has been lost
and is insufficient to continue
operation.
1. Check the LEDs for both
power supplies.
2. Follow the actions in
“Power-supply LEDs” on page
96.
Sensor RAID Error has transitioned
to critical from a less severe state.
Error
A sensor has changed to
Critical state from a less
severe state.
1. Check the hard disk drive
LEDs.
2. Reseat the hard disk drive for
which the status LED is lit.
3. Replace the defective hard
disk drive.
The Drive
n
Status has been
removed from unit Drive 0 Status.
(
n
= hard disk drive number)
Error
A drive has been removed.
Reseat hard disk drive
n
.
(
n
= hard disk drive number)
The Drive
n
Status has been
disabled due to a detected fault.
(
n
= hard disk drive number)
Error
A drive has been disabled
because of a fault.
1. Run the hard disk drive
diagnostic test on drive
n
.
2. Reseat the following
components:
a. Hard disk drive
b. Cable from the system
board to the backplane
3. Replace the following
components one at a time, in
the order shown, restarting
the server each time:
a. Hard disk drive
b. Cable from the system
board to the backplane
c. Hard disk drive backplane
(
n
= hard disk drive number)
Array %1 is in critical condition.
(%1 = CIM_ComputerSystem.
ElementName)
Error
An array is in Critical state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive number)
Replace the hard disk drive that
is indicated by a lit status LED.
Array %1 has failed.
(%1 = CIM_ComputerSystem.
ElementName)
Error
An array is in Failed state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive number)
Replace the hard disk drive that
is indicated by a lit status LED.
Chapter 3. Diagnostics
49
Содержание 7378
Страница 1: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 40: ...22 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 158: ...140 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 166: ...148 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 187: ...Chapter 5 Removing and replacing server components 169...
Страница 192: ...174 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 194: ...176 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 196: ...178 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 318: ...300 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 352: ...334 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 360: ...342 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 361: ......
Страница 362: ...Part Number 00KC028 Printed in USA 1P P N 00KC028...