v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3400 M3 Types 7378 and 7379,” on page 141 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
0058008
DIMM failed memory test
1. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2. Manually re-enable all affected DIMMs if the
server firmware version is older than UEFI v1.10.
If the server firmware version is UEFI v1.10 or
newer, disconnect and reconnect the server to the
power source and restart the server.
3. Swap the affected DIMMs (as indicated by the
error LEDs on the system board or the event
logs) to a different memory channel or
microprocessor (see “Installing a memory module”
on page 231 for memory population).
4. If the problem is related to a DIMM, replace the
failing DIMM (see “Removing a memory module”
on page 230 and “Installing a memory module” on
page 231).
5. (Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector contains any
foreign material or is damaged, replace the
system board (see “Removing the system board”
on page 296 and “Installing the system board” on
page 298).
6. (Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged
pins. If a damage is found, replace the system
board (see “Removing the system board” on page
296 and “Installing the system board” on page
298).
7. (Trained service technician only) If the problem is
related to microprocessor socket pins, replace the
system board (see “Removing the system board”
on page 296 and “Installing the system board” on
page 298).
8. (Trained Service technician only) Replace the
affected microprocessor (see “Removing a
microprocessor and heat sink” on page 284 and
“Installing a microprocessor and heat sink” on
page 286).
0058015
Start to Activate Spare Memory Channel
Information only. A failed DIMM has been detected to
activate the memory online-spare feature. Check the
event log for uncorrected DIMM failure events.
Note:
The memory online-spare feature is supported
on server models with an Intel Xeon
™
5600 series
microprocessor.
Chapter 3. Diagnostics
31
Содержание 7378
Страница 1: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 40: ...22 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 158: ...140 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 166: ...148 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 187: ...Chapter 5 Removing and replacing server components 169...
Страница 192: ...174 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 194: ...176 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 196: ...178 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 318: ...300 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 352: ...334 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 360: ...342 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...
Страница 361: ......
Страница 362: ...Part Number 00KC028 Printed in USA 1P P N 00KC028...