Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 4, “Parts listing, System x3400 M3 Types 7378 and 7379,” on page 141 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Sensor Pwr Rail C Fault has
transitioned to non-recoverable.

Error

A sensor has changed to
Nonrecoverable state.

1. Turn off the server and

disconnect it from power.

2. Remove the hard disk drives,

hard disk drive backplanes,
and DIMMs in connectors 1
through 8.

3. Restart the server.

4. Reinstall each device, one at

a time, starting the server
each time to isolate the failing
device.

5. Replace the failing device.

6. (Trained service technician

only) Replace the system
board.

Sensor Pwr Rail D Fault has
transitioned to non-recoverable.

Error

A sensor has changed to
Nonrecoverable state.

1. Turn off the server and

disconnect it from power.

2. Remove the optical drive and

the DIMMs in connectors 9
through 16.

3. Restart the server.

4. Reinstall the microprocessor

in socket 1 and restart the
server.

5. (Trained service technician

only) Replace the failing
microprocessor.

6. (Trained service technician

only) Replace the system
board.

Sensor Pwr Rail E Fault has
transitioned to non-recoverable.

Error

A sensor has changed to
Nonrecoverable state.

1. Turn off the server and

disconnect it from power.

2. (Trained service technician

only) Remove the optical
drive and the PCI adapter.

3. Restart the server.

4. Reinstall each device, one at

a time, starting the server
each time to isolate the failing
device.

5. Replace the failing device.

6. (Trained service technician

only) Replace the system
board.

Chapter 3. Diagnostics

47

Содержание 7378

Страница 1: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 2: ......

Страница 3: ...IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 4: ...afety Information Environmental Notices and User Guide documents on the IBM Documentation CD and the Warranty Information document that comes with the server Thirteenth Edition June 2014 Copyright IBM...

Страница 5: ...nnectors 20 Chapter 3 Diagnostics 23 Diagnostic tools 23 Event logs 23 Viewing event logs through the Setup utility 24 Viewing event logs without restarting the server 24 POST error codes 26 System ev...

Страница 6: ...alling a ServeRAID adapter battery 158 Removing the battery 160 Installing the battery 162 Internal cable routing and connectors 164 Tape drive cable connection 164 DVD drive cable connection 167 Oper...

Страница 7: ...backplate 261 Installing the simple swap backplate 263 Removing the 2 5 inch disk drive cage 265 Installing the 2 5 inch disk drive cage 267 Removing and replacing FRUs 268 Removing the upper 3 5 inch...

Страница 8: ...al assistance 325 Before you call 325 Using the documentation 325 Getting help and information from the World Wide Web 325 Software service and support 326 Hardware service and support 326 IBM Taiwan...

Страница 9: ...ety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazio...

Страница 10: ...s a damaged CRT face or a bulging capacitor v Mechanical hazards such as loose or missing hardware To inspect the product for potential unsafe conditions complete the following steps 1 Make sure that...

Страница 11: ...anical inspection work near power supplies or remove or install main units v Before you work on the equipment disconnect the power cord If you cannot disconnect the power cord have the customer power...

Страница 12: ...tement is labeled Statement 1 translations for that caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statements in this document before...

Страница 13: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Страница 14: ...replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immerse into water v...

Страница 15: ...e device v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Cla...

Страница 16: ...d the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the devic...

Страница 17: ...resent inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement...

Страница 18: ...pecifications Statement 15 CAUTION Make sure that the rack is secured properly to avoid tipping when the server unit is extended Statement 17 CAUTION The following label indicates moving parts nearby...

Страница 19: ...ollection is necessary for diagnosing hardware and software problems a Document error codes and system board LEDs v System error codes See Viewing the test log on page 98 for information about error c...

Страница 20: ...c code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 1 Determine...

Страница 21: ...configured correctly Many configuration problems are caused by loose power or signal cables or incorrectly seated adapters You might be able to solve the problem by turning off the server reconnecting...

Страница 22: ...ot diagnose the problem use the procedure for another symptom if possible If the problem remains contact IBM or an approved warranty service provider for assistance with additional problem determinati...

Страница 23: ...n document Related documentation In addition to this document the following documentation also comes with the server v Environmental Notices and User s Guide This document is in PDF on the IBM Documen...

Страница 24: ...described in this document 1 Go to http www ibm com support 2 Under Product support click System x 3 Under Popular links click Publications lookup 4 From the Product family menu select System x3400 an...

Страница 25: ...GB of memory is installed in the server before you run DSA from a bootable CD v Maximum 128 GB 48 GB using unbuffered DIMMs UDIMMs 128 GB using registered DIMMs RDIMMs v Type Registered or unbuffered...

Страница 26: ...B ports standard v2 0 supporting v1 1 Four on rear of server Two on front of server v One internal USB tape connector v One Broadcom dual port 10 100 1000 Ethernet controller with Wake on LAN support...

Страница 27: ...ound pressure levels in a given location might exceed the average stated values because of room reflections and other nearby noise sources The declared sound power levels indicate an upper limit below...

Страница 28: ...rd disk drive activity LED some models On some server models each hot swap drive has a hard disk drive activity LED When this green LED is flashing it indicates that the drive is in use When the drive...

Страница 29: ...h the AC and DC power LEDs are lit DC power LED This green LED provides status information about the power supply During typical operation both the AC and DC power LEDs are lit Power error Fault LED W...

Страница 30: ...s LED is lit it indicates that there is activity between the server and the network Ethernet link status LED This LED is on the Ethernet connector When this LED is lit it indicates that there is an ac...

Страница 31: ...econd power supply is providing power to the server Off On Off Faulty power supply Replace the power supply Off On On Faulty power supply Replace the power supply On Off Off Power supply not fully sea...

Страница 32: ...AC power source and the power supply has detected an internal problem Off On Off Faulty power supply Off On On Faulty power supply On Off Off Power supply not fully seated faulty system board or fault...

Страница 33: ...section show the LEDs connectors and jumpers on the internal boards The illustrations might differ slightly from your hardware System board internal connectors The following illustration shows the int...

Страница 34: ...that is available on the PCI Express extender card if equipped The following illustration shows two additional PCI X expansion slots that are available on the PCI X extender card if equipped 16 IBM S...

Страница 35: ...2 and 3 TPM physical presence is not asserted default Note The physical presence requires manual setting on the server to change the TPM configuration The TPM is enabled and physical presence is not a...

Страница 36: ...he server then disconnect all power cords and external cables Review the information in Safety on page vii Installation guidelines on page 149 and Handling static sensitive devices on page 151 18 IBM...

Страница 37: ...ard is equipped with a PCI extender card that provides either one or two additional expansion slots The following illustration shows the LEDs on the PCI Express extender card if equipped The following...

Страница 38: ...system board Video port Serial port NMI button USB ports Ethernet System management Hard disk drive backplane connectors The following illustrations show the connectors on the 2 5 inch and 3 5 inch h...

Страница 39: ...Figure 1 Connectors on the 3 5 inch hard disk drive backplane Figure 2 Connectors on the 2 5 inch hard disk drive backplane Chapter 2 Introduction 21...

Страница 40: ...22 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 41: ...codes The diagnostic programs are the primary method of testing the major components of the server See Diagnostic programs messages and error codes on page 97 for more information Event logs Error co...

Страница 42: ...ride or remove it You must replace the system board Viewing event logs without restarting the server If the server is not hung methods are available for you to view one or more event logs without havi...

Страница 43: ...le describes the methods that you can use to view the event logs depending on the condition of the server The first two conditions generally do not require that you restart the server Table 6 Methods...

Страница 44: ...ervice technician only that step must be performed only by a trained service technician Error code Description Action 0010002 Microprocessor not supported 1 Reseat the following components one at a ti...

Страница 45: ...microprocessor 2 3 Replace the following components one at a time in the order shown restarting the server each time a Trained service technician only Microprocessor b Trained service technician only...

Страница 46: ...the server to the power source and restart the server 3 If the problem remains replace the failing DIMM see Removing a memory module on page 230 and Installing a memory module on page 231 4 Trained se...

Страница 47: ...a microprocessor and heat sink on page 284 and Installing a microprocessor and heat sink on page 286 5 Trained service technician only Replace the system board see Removing the system board on page 2...

Страница 48: ...d DIMM 4 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board...

Страница 49: ...a memory module on page 230 and Installing a memory module on page 231 5 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector con...

Страница 50: ...cted DIMM failure events see Event logs on page 23 00580A6 Spare Memory Channel Activated Information only Memory online spare channel has been activated to back up a failed DIMM Check the event log f...

Страница 51: ...apters from the extender card 5 Replace the following components one at a time in the order shown restarting the server each time a Extender card b Trained service technician only System board 2018002...

Страница 52: ...y server firmware settings 2 Turn off the server and remove it from the power source 3 Reconnect the server to the power source and then turn on the server 305000A RTC date time is incorrect 1 Adjust...

Страница 53: ...configuration error 1 Remove any recent configuration changes that you made in the Setup utility 2 Run the Setup utility select Load Default Settings and save the settings 3808000 IMM communication f...

Страница 54: ...e system board 3818004 Core Root of Trust Measurement CRTM system error 1 Run the Setup utility select Load Default Settings and save the settings 2 Trained service technician only Replace the system...

Страница 55: ...erformed only by a trained service technician Message Severity Description Action Numeric sensor Ambient Temp going high upper critical has asserted Error An upper critical sensor going high has asser...

Страница 56: ...e levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA pro...

Страница 57: ...code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Make sure that the installed microproce...

Страница 58: ...of code is supported for the cluster solution before you update the code 2 Make sure that the installed microprocessors are compatible with each other see Installing a microprocessor and heat sink on...

Страница 59: ...ice technician only Replace microprocessor n n microprocessor number Sensor CPU nOverTemp has transitioned to critical from a non recoverable state n microprocessor number Error A sensor has changed t...

Страница 60: ...imeout has occurred on system 1 1 CIM_ComputerSystem ElementName Error A bus timeout has occurred 1 Remove the adapter from the PCI slot that is indicated by a lit LED 2 Replace the extender card 3 Re...

Страница 61: ...nt Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solutio...

Страница 62: ...rdinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Make sure that the two micropr...

Страница 63: ...ed code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Trained service technician only Repl...

Страница 64: ...emove the PCI adapter and microprocessor 1 Reinstall the microprocessor in socket 1 and restart the server 3 Restart the server 4 Reinstall each device one at a time starting the server each time to i...

Страница 65: ...device 5 Replace the failing device 6 Trained service technician only Replace the system board Sensor Pwr Rail D Fault has transitioned to non recoverable Error A sensor has changed to Nonrecoverable...

Страница 66: ...om a less severe state 1 Make sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Replace power supply n n power supply number Sensor PSn 12V OV Fault...

Страница 67: ...k drive The Drive n Status has been removed from unit Drive 0 Status n hard disk drive number Error A drive has been removed Reseat hard disk drive n n hard disk drive number The Drive n Status has be...

Страница 68: ...IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If...

Страница 69: ...has occurred 5 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the syste...

Страница 70: ...error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any...

Страница 71: ...M disabled for All DIMMs on Memory Subsystem All DIMMs Info DIMM disabled 1 Make sure the DIMM is installed correctly see Installing a memory module on page 231 2 If the DIMM was disabled because of a...

Страница 72: ...ck the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v...

Страница 73: ...e error has occurred 5 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace th...

Страница 74: ...error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any...

Страница 75: ...led for One of the DIMMs on Memory Subsystem One of the DIMMs Info DIMM disabled 1 Make sure the DIMM is installed correctly see Installing a memory module on page 231 2 If the DIMM was disabled becau...

Страница 76: ...t website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the serve...

Страница 77: ...MM connector If the connector contains any foreign material or is damaged replace the system board see Removing the system board on page 296 and Installing the system board on page 298 6 Trained servi...

Страница 78: ...eck the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs if the server firmware version is older than UEFI...

Страница 79: ...le error has occurred 5 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace t...

Страница 80: ...ror still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any fo...

Страница 81: ...mory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the IBM support website for an applicable retain tip or firmwa...

Страница 82: ...els or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove the adapter f...

Страница 83: ...coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove both adapters 5 Rep...

Страница 84: ...the system board Redundancy Bckup Mem Status has been reduced Error Redundancy has been lost and is insufficient to continue operation 1 Check the system event log for DIMM failure events uncorrectabl...

Страница 85: ...g No action information only Ethernet Duplex setting modified from 1 to 2 by user 3 1 CIM_EthernetPort NetworkAddresses 2 CIM_EthernetPort NetworkAddresses 3 user ID Info A user has modified the Ether...

Страница 86: ...user ID 2 ValueMap CIM_ProtocolEndpoint ProtocolIFType 3 IP address xxx xxx xxx xxx Info A user has successfully logged in to the IMM No action information only Attempting to 1 server 2 by user 3 1 P...

Страница 87: ...t login ID and password are being used 2 Have the system administrator reset the login ID or password The Chassis Event Log CEL on system 1 cleared by user 2 1 CIM_ComputerSystem ElementName 2 user ID...

Страница 88: ...r has occurred and the screen capture was successful 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_eth...

Страница 89: ...e updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code IMM reset was caused by restoring default va...

Страница 90: ...ull When the log is full older log entries are replaced by newer ones To avoid losing older log entries save the log as a text file and clear the log 1 Platform Watchdog Timer expired for 2 1 OS Watch...

Страница 91: ...her the failing server is part of a shared hard disk drive cluster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones t...

Страница 92: ...operator information panel see Server controls LEDs and connectors on page 9 If it is flashing check the light path diagnostics LEDs see Light path diagnostics on page 90 h Check for the following res...

Страница 93: ...7378 and 7379 on page 141 to determine which components are customer replaceable units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service tech...

Страница 94: ...hnician The server is hung while the screen is on Cannot start the Setup utility by pressing F1 1 See Nx boot failure on page 136 for more information 2 See Recovering the server firmware on page 134...

Страница 95: ...termine which components are customer replaceable units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be pe...

Страница 96: ...the order in which they are listed in the Action column until the problem is solved v See Chapter 4 Parts listing System x3400 M3 Types 7378 and 7379 on page 141 to determine which components are cus...

Страница 97: ...The mouse or pointing device is compatible with the server See http www ibm com servers eserver serverproven compat us v The mouse or pointing device cable is securely connected to the server v The m...

Страница 98: ...k when it detected a problem or a memory bank might have been manually disabled 2 Check the POST error log v If a DIMM was disabled by a systems management interrupt SMI replace the DIMM v If a DIMM w...

Страница 99: ...y If the failures continue after all identified pairs are replaced go to step4 3 Return the removed DIMMs one pair at a time to their original connectors restarting the server after each pair until a...

Страница 100: ...ch in speed and cache size 3 Trained service technician only Reseat microprocessor 1 4 Trained service technician only If there is no indication of which microprocessor has failed isolate the error by...

Страница 101: ...is blank 1 If the server is attached to a KVM switch bypass the KVM switch to eliminate it as a possible cause of the problem connect the monitor cable directly to the correct connector on the rear o...

Страница 102: ...images If this happens turn off the monitor Attention Moving a color monitor while it is turned on might cause screen discoloration Move the device and the monitor at least 305 mm 12 in apart and tur...

Страница 103: ...installed correctly v You have not loosened any other installed devices or cables v You updated the configuration information in the Setup utility Whenever memory or any other device is changed you mu...

Страница 104: ...not indicate a problem v The microprocessors are installed in the correct sequence 3 Reseat the following components a DIMMs b Trained service technician only Power switch connector c Trained service...

Страница 105: ...e units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a trained service technician Sym...

Страница 106: ...e The ServeRAID Manager program cannot view all installed drives or the operating system cannot be installed 1 Make sure that the hard disk drive is connected correctly 2 Make sure that the SAS hard d...

Страница 107: ...omes with the software for a description of the messages and suggested solutions to the problem 3 Contact the software vendor Universal Serial Bus USB port problems v Follow the suggested actions in t...

Страница 108: ...RU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a trained service technician Lit light pa...

Страница 109: ...nits CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a trained service technician Lit li...

Страница 110: ...or lit LEDs Certain components inside the server have LEDs that are lit to indicate the location of a problem The following illustration shows the LEDs on the system board 92 IBM System x3400 M3 Types...

Страница 111: ...trained service technician Lit light path diagnostics LED with the system error or information LED also lit Description Action DIMM 1 to DIMM 16 error LEDs A DIMM has failed or is incorrectly install...

Страница 112: ...ailing microprocessor 4 Replace the following components one at a time in the order shown restarting the server each time a Trained service technician only Failing microprocessor b Trained service tec...

Страница 113: ...shing within 30 seconds of when the server is connected to power complete the following steps 1 Trained service technician only Use the IMM recovery switch to recover the firmware see Table 5 on page...

Страница 114: ...esent Off Off On No AC power to the server or a problem with the AC power source and the power supply had detected an internal problem 1 Replace the power supply 2 Make sure that the power cord is con...

Страница 115: ...ment again 5 Type gui to display the graphical user interface or select cmd to display the DSA interactive menu 6 Follow the instructions on the screen to select the diagnostic test to run If the diag...

Страница 116: ...name for the saved log file Notes 1 To create and use a diskette you must add an optional external diskette drive to the server 2 To save the test log to a diskette you must use a diskette that you ha...

Страница 117: ...est level of DSA code go to http www ibm com support docview wss uid psg1SERV DSA 3 Run the test again 4 Make sure that the system firmware is at the latest level The installed firmware level is shown...

Страница 118: ...o to http www ibm com support docview wss uid psg1SERV DSA 3 Run the test again 4 Make sure that the system firmware is at the latest level The installed firmware level is shown in the DSA log in the...

Страница 119: ...again 8 Replace the following components one at a time in the order shown and run this test again to determine whether the problem has been solved a Trained service technician only Microprocessor boar...

Страница 120: ...l is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site...

Страница 121: ...are level is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM...

Страница 122: ...l is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site...

Страница 123: ...The installed firmware level is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure rem...

Страница 124: ...DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubles...

Страница 125: ...re level is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM W...

Страница 126: ...shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for...

Страница 127: ...The installed firmware level is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure re...

Страница 128: ...Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubleshooting informa...

Страница 129: ...DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubles...

Страница 130: ...g in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubleshootin...

Страница 131: ...ponent For more information see Updating the firmware on page 302 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubleshooting information at http www ibm com systems...

Страница 132: ...Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm com support docview wss uid psg1SERV DSA 5 Make sure that the IMM firmware i...

Страница 133: ...DSA code go to http www ibm com support docview wss uid psg1SERV DSA 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA log in the Firmware VPD s...

Страница 134: ...e system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm com support docview ws...

Страница 135: ...he system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm com support docview w...

Страница 136: ...led firmware level is shown in the DSA log in the Firmware VPD section for this component For more information see Updating the firmware on page 302 6 Run the test again 7 Turn off the system and disc...

Страница 137: ...rmation at http www ibm com systems support supportsite wss docdisplay brandind 5000008 lndocid SERV CALL 201 803 xxx Memory Memory Test Aborted Test aborted could not enable the processor cache 1 Tur...

Страница 138: ...lay brandind 5000008 lndocid SERV CALL 201 806 xxx Memory Memory Test Aborted Test aborted the memory controller fast scrub operation was not completed 1 Turn off and restart the system 2 Run the test...

Страница 139: ...ng fast scrub 1 Turn off and restart the system 2 Run the test again 3 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm com support docview wss ui...

Страница 140: ...tion see Updating the firmware on page 302 6 Run the test again 7 Replace the failing DIMMs 8 Re enable all memory in the Setup utility see Using the Setup utility on page 303 9 Run the test again 10...

Страница 141: ...utility on page 303 2 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm com support docview wss uid psg1SERV DSA 3 Run the test again 4 Run the sta...

Страница 142: ...t the latest level For the latest level of DSA code go to http www ibm com support docview wss uid psg1SERV DSA 2 Run the test again 3 Check the drive cabling at both ends for loose or broken connecti...

Страница 143: ...n connections or damage to the cable Replace the cable if it is damaged 6 Run the test again 7 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www ibm co...

Страница 144: ...dditional troubleshooting information go to http www ibm com support docview wss uid psg1MIGR 41559 6 Run the test again 7 Replace the CD DVD drive 8 If the failure remains go to the IBM Web site for...

Страница 145: ...ibm com support docview wss uid psg1SERV DSA 6 Run the test again 7 For additional troubleshooting information go to http www ibm com support docview wss uid psg1MIGR 41559 8 Run the test again 9 Repl...

Страница 146: ...st Failed An error was found in the tape alert log page 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Clear the error log 4 Run the test agai...

Страница 147: ...r tape drives and libraries can be found at http www ibm com systems support 6 Run the test again 7 If the failure remains go to the IBM Web site for more troubleshooting information at http www ibm c...

Страница 148: ...e found at http www ibm com systems support 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Make sure that the firmware is at the latest level Software fo...

Страница 149: ...1 xxx Broadcom Ethernet Device Test MII Registers Failed 1 Make sure that the component firmware is at the latest level The installed firmware level is shown in the DSA log in the Firmware VPD section...

Страница 150: ...e adapter Check the PCI Information and Network Settings information in the DSA log to determine the physical location of the failing component 5 If the failure remains go to the IBM Web site for more...

Страница 151: ...ical Layer Failed 1 Check the Ethernet cable for damage and make sure that the cable type and connection are correct 2 Make sure that the component firmware is at the latest level The installed firmwa...

Страница 152: ...from what is described in this document 1 Go to http www ibm com systems support 2 Under Product support click System x 3 Under Popular links click Software and device drivers 4 Click System x3400 M3...

Страница 153: ...type filename s where filename is the name of the executable file that you downloaded with the firmware update package Monitor the firmware update until completion 14 Turn off the server and disconne...

Страница 154: ...primary bank Out of band method See the IMM documentation Automated boot recovery ABR While the server is starting if the integrated management module detects problems with the server firmware in the...

Страница 155: ...one at a time until the problem is isolated Solving Ethernet controller problems The method that you use to test the Ethernet controller depends on which operating system you are using See the operati...

Страница 156: ...assword switch 2 SW4 to override the power on password and clear the CMOS memory see Internal LEDs connectors and jumpers on page 15 Check the LEDs on all the power supplies see Power supply LEDs on p...

Страница 157: ...ure occur on a single server or on multiple servers Is the failure repeatable Has this configuration ever worked What changes if any were made before the configuration failed Is this the original repo...

Страница 158: ...140 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 159: ...142 For an updated parts listing on the Web complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this...

Страница 160: ...etting service and assistance see the Warranty Information document Table 9 Parts listing Type 7378 7379 Index Description CRU part number Tier 1 CRU part number Tier 2 FRU part number 1 Power supply...

Страница 161: ...essor Intel Xeon E5620 4 core 2 40 GHz 12 MB 1066 MHz 80 W 49Y7053 20 Microprocessor Intel Xeon L5640 6 core 2 26 GHz 12 MB 1333 MHz 60 W 49Y7054 20 Microprocessor Intel Xeon L5630 4 core 2 13 GHz 12...

Страница 162: ...e swap 49Y4514 Cable operator information panel 41Y9082 Cable backplane configuration 2 5 inch HDD 69Y1331 Cable backplane configuration 3 5 inch HDD 46D1401 Cable Backplane Power 2 5 inch HDD 69Y1326...

Страница 163: ...tore Table 10 Consumable parts Type 7378 7379 Index Description Part number ServeRAID battery 43W4342 To order a consumable part complete the following steps 1 Go to http www ibm com 2 From the Produc...

Страница 164: ...mey Djibouti Egypt Equatorial Guinea Eritrea Estonia Ethiopia Finland France French Guyana French Polynesia Germany Greece Guadeloupe Guinea Guinea Bissau Hungary Iceland Indonesia Iran Kazakhstan Kyr...

Страница 165: ...ted States of America Venezuela 39M5512 110 120 V Antigua and Barbuda Aruba Bahamas Barbados Belize Bermuda Bolivia Caicos Islands Canada Cayman Islands Colombia Costa Rica Cuba Dominican Republic Ecu...

Страница 166: ...148 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 167: ...page vii and the guidelines in Handling static sensitive devices on page 151 This information will help you work safely v Observe good housekeeping in the area where you are working Place removed cov...

Страница 168: ...turn on the server Operating the server for extended periods of time more than 30 minutes with the server cover removed might damage server components v You have followed the cabling instructions tha...

Страница 169: ...age touch it to an unpainted metal part on the outside of the server for at least 2 seconds This drains static electricity from the package and from your body v Remove the device from its package and...

Страница 170: ...eft side of the bezel away from the server 5 From inside of the top section of the bezel door slide the blue tab up to unlock the bezel media door then grasp the depressed area on the media door and p...

Страница 171: ...6 When the media door is unlocked the icon on the side of the bezel will be in the unlocked position Media door icon Chapter 5 Removing and replacing server components 153...

Страница 172: ...access to the air baffle microprocessors and DIMMs To open the power supply cage complete the following steps 1 Read the safety information that begins on page vii and Handling static sensitive device...

Страница 173: ...pply cage handle to unlock the cage then rotate the cage out until it stops The tab on the rear power supply latch bracket clicks into place when the cage is completely out of the way 6 Let the power...

Страница 174: ...bracket Power supply support bracket Power supply release tab 2 Rotate the power supply cage into the server chassis The locating tabs on the power supply cage must fit over the corresponding tabs on...

Страница 175: ...D adapter has a battery on it and you need to replace it complete the following steps 1 Read the safety information that begins on page vii and Handling static sensitive devices on page 151 2 Turn off...

Страница 176: ...the RAID adapter battery in the server complete the following steps 1 Read the safety information that begins on page vii and Handling static sensitive devices on page 151 2 Turn off the server and a...

Страница 177: ...the ServeRAID adapter on the system board see Installing an adapter on page 215 9 Install and lock the left side cover see Installing the left side cover on page 181 10 Reconnect the external cables a...

Страница 178: ...the server to fall over 5 Unlock and remove the left side cover see Removing the left side cover on page 181 6 Remove the battery a Use one finger to tilt the battery horizontally out of its socket p...

Страница 179: ...7 Dispose of the battery as required by local ordinances or regulations see the Environmental Notices and User Guide for more information Chapter 5 Removing and replacing server components 161...

Страница 180: ...ies call 1 800 426 7378 within the United States and 1 800 465 7999 or 1 800 465 6666 within Canada Outside the U S and Canada call your IBM marketing representative or authorized reseller v After you...

Страница 181: ...battery in a vertical orientation so that the smaller side is facing the socket b Tilt the battery and slide the battery into its socket then press the battery toward the socket until it clicks into p...

Страница 182: ...tached If you replace any drives remember which cable is attached to which drive v When you route a cable make sure that it does not block the airflow to the rear of the drives or over the microproces...

Страница 183: ...nal power converter cable when you install an RDX internal USB tape drive in the server This cable comes with the server in the plastic bag with the drive rails Connects to tape drive Connects to opti...

Страница 184: ...Power converter cable Optical power cable SATA connector Tape drive 166 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 185: ...ect the cable by using excessive force Failing to remove the cable properly may damage the connectors on the system board Any damage to the connectors may require replacing the system board The follow...

Страница 186: ...raSlim DVD drive to the system board Operator information panel cable connection The following illustration shows the internal cable routing and connectors from the operator information panel to the s...

Страница 187: ...Chapter 5 Removing and replacing server components 169...

Страница 188: ...drives 1 The following illustrations show the connectors on the 2 5 inch and 3 5 inch hard disk drive backplanes Figure 3 Connectors on the 3 5 inch hard disk drive backplane Figure 4 Connectors on th...

Страница 189: ...next in sequence to a ServeRAID adapter with battery backup module for example if a ServeRAID adapter with battery backup module is installed in slot 2 do not install any card in slot 3 Figure 5 Cabl...

Страница 190: ...e to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID ada...

Страница 191: ...5 inch hot swap hard disk drives v The following illustration shows the internal power cable routing v The following illustration shows the internal configuration cable routing v The following illustr...

Страница 192: ...174 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 193: ...lustration shows the internal power cable routing v The following illustration shows the internal configuration cable routing v The following illustration shows the internal signal cable routing for i...

Страница 194: ...176 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 195: ...lustration shows the internal power cable routing v The following illustration shows the internal configuration cable routing v The following illustration shows the internal signal cable routing for i...

Страница 196: ...178 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 197: ...2 5 inch hot swap hard disk drives v The following illustration shows the internal power cable routing v The following illustration shows the internal configuration cable routing Chapter 5 Removing an...

Страница 198: ...nternal signal cable routing for installing a ServeRAID adapter and a ServeRAID expansion adapter Note SAS expander card does not support 3 GB RAID adapters 180 IBM System x3400 M3 Types 7378 and 7379...

Страница 199: ...non hot swap component turn off the server and all peripheral devices and disconnect the power cords and all external cables 3 Unlock the left side cover using the key that comes with the server 4 Pul...

Страница 200: ...ide cover on the bottom ledge of the server 2 Rotate the top edge of the cover toward the server and press inward on the cover until it clicks into place 3 Lock the cover using the key that comes with...

Страница 201: ...peration using a ServeRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and c...

Страница 202: ...n the 3 5 inch hot swap SAS or hot swap SATA hard disk drive server models Figure 8 server with sixteen 2 5 inch hard disk drives Figure 9 server with four 3 5 inch hard disk drives 184 IBM System x34...

Страница 203: ...ves You can install removable media drives only in bays 1 2 and 3 on models with four 3 5 inch eight or sixteen 2 5 inch hard disk drives v To install a 3 5 in drive in a 5 25 in bay you must use a 5...

Страница 204: ...sult in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when you work inside the server with the power on 2 Unlock the left...

Страница 205: ...en pull the drive out of the drive bay 5 If you are instructed to return the hot swap hard disk drive follow all packaging instructions and use any packaging materials for shipping that are supplied t...

Страница 206: ...proper cooling do not install any card in the slot next in sequence to a ServeRAID adapter with battery backup module for example if a ServeRAID adapter with battery backup module is installed in slot...

Страница 207: ...ap bay 5 Rotate the drive handle down until the drive is seated in the hot swap bay and the release latch clicks into place Notes a After you install the hard disk drive check the disk drive status LE...

Страница 208: ...dling static sensitive devices on page 151 2 Unlock the left side cover Note You must unlock the left side cover to open or remove the bezel When you lock the left side cover it locks both the cover a...

Страница 209: ...structed to return the 3 5 inch hot swap hard disk drive follow all packaging instructions and use any packaging materials for shipping that are supplied to you Chapter 5 Removing and replacing server...

Страница 210: ...rive from the package and place it on a static protective surface 3 Make sure that the drive tray handle is in the open position 4 Align the drive assembly with the guide rails in the bay then careful...

Страница 211: ...fter you install hard disk drives See the RAID documentation on the IBM Web site at http www ibm com systems support for information about RAID adapters 7 Close the bezel 8 Lock the left side cover Ch...

Страница 212: ...n page vii and Handling static sensitive devices on page 151 2 Turn off the server and all attached devices then disconnect all power cords and external cables 3 Unlock the left side cover Note You mu...

Страница 213: ...n pull the drive assembly out of the bay and set it aside 7 If you are instructed to return the simple swap hard disk drive follow all packaging instructions and use any packaging materials for shippi...

Страница 214: ...kage and place it on a static protective surface 2 Align the drive assembly with the guide rails in the bay 3 Pull the loops of the drive assembly toward each other then carefully slide the drive asse...

Страница 215: ...ding system when you work inside the server with the power on 2 Unlock and remove the left side cover see Removing the left side cover on page 181 Attention To ensure proper system cooling do not leav...

Страница 216: ...problem always use an electrostatic discharge wrist strap or other grounding system when you work inside the server with the power on 2 Touch the static protective package that contains the hot swap...

Страница 217: ...evices and disconnect the power cords and all external cables c Unlock and remove the left side cover see Removing the left side cover on page 181 d Open the bezel by pressing the button on the left e...

Страница 218: ...following steps a Read the safety information that begins on page vii and Handling static sensitive devices on page 151 b Turn off the server and peripheral devices and disconnect the power cords and...

Страница 219: ...way up until the retainer latch locks the cage in place on the chassis f Remove the air baffle see Removing the air baffle on page 212 g Remove the fan cage assembly see Removing the fan cage assembly...

Страница 220: ...lide the drive retention clip from the side of the drive Save the clip to use when you install the replacement drive or replace the UltraSlim DVD drive filler m If you are instructed to return the Ult...

Страница 221: ...h as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous l...

Страница 222: ...ternal cables e Unlock and remove the left side cover see Removing the left side cover on page 181 f Remove the fan cage assembly see Removing the fan cage assembly on page 243 g Open the bezel by pre...

Страница 223: ...to set jumpers or switches if there are any Note You might find it easier to install the new drive from the front and then attach the cables j Align the rails on the DVD drive with the guides in the d...

Страница 224: ...ps v Locate the documentation that comes with the drive and follow those instructions in addition to the instructions in this chapter v Make sure that you have all the cables and other equipment that...

Страница 225: ...ectly with optical instruments and avoid direct exposure to the beam Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 b Touch the static protective p...

Страница 226: ...y cage assembly all the way up until the retainer latch locks the cage in place on the chassis h Remove the air baffle see Removing the air baffle on page 212 i Remove the fan cage assembly see Removi...

Страница 227: ...VD drive through the slim slot on top of the 3 5 inch hard disk drive cage l Connect the power and signal cables to the UltraSlim DVD drive See Internal cable routing and connectors on page 164 for mo...

Страница 228: ...ning of the server along the lower edge of the opening Note Pull the power and signal cables of the UltraSlim DVD drive into the upper opening of the server first Make sure the cables are not stuck wh...

Страница 229: ...the power supply cage assembly into the chassis u Close the bezel v Install and lock the left side cover see Installing the left side cover on page 181 w Reconnect the external cables and power cords...

Страница 230: ...e left side cover on page 181 5 Remove the power supply or power supplies from the power supply cage see Removing a hot swap power supply on page 273 6 Rotate the power supply cage to its open positio...

Страница 231: ...into place 3 Rotate the rear hinged part of the air baffle down to the system board Note Make sure that the power supply cage cables are not caught under the air baffle 4 Return the power supply cage...

Страница 232: ...rver to fall over 4 Unlock and remove the left side cover see Removing the left side cover on page 181 5 Rotate the adapter retention brackets to the open position 6 Disconnect the cables from the ada...

Страница 233: ...ss x16 slot with x8 links PCI Express 1 0a compliant Slots 3 and 4 are PCI Express x8 slots with x4 links PCI Express 1 0a compliant Slot 5 is a PCI Express x8 slot with x8 links PCI Express 1 0a comp...

Страница 234: ...ling instructions and information about jumper or switch settings It might be easier for you to route cables before you install the adapter 2 Touch the static protective package that contains the adap...

Страница 235: ...k the left side cover see Installing the left side cover on page 181 11 Reconnect the external cables and power cords then turn on the attached devices and turn on the server Note If the server is con...

Страница 236: ...ters and place the adapters on a static protective surface see Removing an adapter on page 214 Note You might find it helpful to note where each adapter is installed before you remove the adapters 5 R...

Страница 237: ...the chassis then insert the top hinge point into the matching hole 2 Install the adapters see Installing an adapter on page 215 3 Close the rear adapter retention bracket 4 Install and lock the left s...

Страница 238: ...wing steps 1 Read the safety information that begins on page vii and Handling static sensitive devices on page 151 2 Turn off the server and peripheral devices and disconnect the power cords and all e...

Страница 239: ...able from the system board see System board internal connectors on page 15 10 Locate the operator information panel assembly release latch just above the DVD drive 11 Push up on the release latch whil...

Страница 240: ...the system board see System board internal connectors on page 15 and Internal cable routing and connectors on page 164 5 Install the fan cage assembly see Installing the fan cage assembly on page 244...

Страница 241: ...e left side cover see Removing the left side cover on page 181 5 Remove the hot swap power supply or power supplies from the power supply cage see Removing a hot swap power supply on page 273 6 Rotate...

Страница 242: ...he VRM straight down into the connector by applying pressure on both ends of the VRM simultaneously The retaining clips snap into the locked position when the VRM is seated in the connector 5 Install...

Страница 243: ...flat and facing up Note Be careful and do not drop the server 5 Rotate the adapter retention brackets to the open position 6 Remove any adapters that prevent you from accessing the virtual media key c...

Страница 244: ...nline memory modules DIMMs that your server supports and other information that you must consider when you install DIMMs Attention Do not mix UDIMMs and RDIMMs in the same server v The server supports...

Страница 245: ...er and the configured PCI devices Note If you install a ServeRAID M1015 SAS SATA adapter make sure at least 2 GB of memory is installed in the server before you run DSA from a bootable CD Independent...

Страница 246: ...v The maximum amount of available memory is reduced to half of the amount of installed memory when memory mirroring is enabled For example if you install 64 GB of memory only 32 GB of addressable mem...

Страница 247: ...or First pair of DIMMs 1 3 6 Second pair of DIMMs 1 2 5 Third pair of DIMMs 1 1 4 Fourth pair of DIMMs 2 14 11 Fifth pair of DIMMs 2 13 10 Sixth pair of DIMMs 2 12 9 Note DIMM connectors 7 8 15 and 16...

Страница 248: ...2 DIMM slots 1 4 9 and 12 are not used in memory sparing mode Removing a memory module Retaining clip DIMM To remove a dual inline memory module DIMM complete the following steps 1 Read the safety in...

Страница 249: ...erials for shipping that are supplied to you Installing a memory module To install a memory module complete the following steps 1 Locate the DIMM connectors on the system board see System board intern...

Страница 250: ...d lock the left side cover see Installing the left side cover on page 181 11 Reconnect the external cables and power cords then turn on the attached devices and turn on the server In two DIMM per chan...

Страница 251: ...data bus 10600 10 66 GBps PC3 1333 SDRAMs 8 byte primary data bus 12800 12 80 GBps PC3 1600 SDRAMs 8 byte primary data bus m is the DIMM type E Unbuffered DIMM UDIMM with ECC x72 bit module data bus R...

Страница 252: ...Number of DIMMs DIMM type DIMM size Total memory 12 Single rank UDIMMs 2 GB 24 GB 12 Dual rank UDIMMs 4 GB 48 GB 16 Single rank RDIMMs 2 GB 32 GB 16 Dual rank RDIMMs 2 GB 32 GB 16 Dual rank RDIMMs 4 G...

Страница 253: ...ward the system board 5 Grasp the flash device and pull to remove it from the connector 6 Return the retention latch to the locked position by pulling it away from the system board 7 If you are instru...

Страница 254: ...latch to the locked position by pulling it away from the system board 7 Reconnect the power cord and any cables that you removed 8 Install the cover see Installing the left side cover on page 181 9 T...

Страница 255: ...5 Grasp the upgrade key and lift to remove it from connector on the ServeRAID adapter 6 Close the rear adapter retention bracket Chapter 5 Removing and replacing server components 237...

Страница 256: ...dvanced feature key To install an optional ServeRAID adapter advanced feature key complete the following steps 1 Read the safety information that begins on page vii and Installation guidelines on page...

Страница 257: ...bezel complete the following steps 1 Read the safety information that begins on page vii and Handling static sensitive devices on page 151 2 Unlock the left side cover Note You must unlock the left s...

Страница 258: ...bly toward each other and pull the hinge assemblies out of the chassis Note You might need a flat blade screwdriver to pry the hinge assemblies out of the chassis 240 IBM System x3400 M3 Types 7378 an...

Страница 259: ...alarmed because this is how the bezel was designed The bezel is designed with breakaway hinges so that you can easily reattach it to the chassis 5 If you are instructed to return the bezel follow all...

Страница 260: ...place 3 If you removed the bezel by detaching the sliding hinge mount from the hinge assembly using the breakaway method as the bezel was designed for complete the following steps to reattach the bez...

Страница 261: ...4 Close the bezel 5 Lock the left side cover Removing the fan cage assembly To remove the fan cage assembly complete the following steps 1 Read the safety information that begins on page vii and Hand...

Страница 262: ...he server The fan cage will lift up slightly when the release latches are fully open 10 Grasp the fan cage assembly and lift it out of the server 11 If you are instructed to return the fan cage assemb...

Страница 263: ...le on page 213 5 Return the power supply cage to its closed position see Closing the power supply cage on page 156 6 Install the hot swap power supply or power supplies see Installing a hot swap power...

Страница 264: ...151 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables 3 Unlock and remove the left side cover see Removing the left side cover on page 181 4 Open the...

Страница 265: ...the server 7 Note the location of the blue rails on the tape drive then remove the blue rails and save them for future use 8 Gently pull the tape drive out of the server 9 If you are instructed to re...

Страница 266: ...ce 5 Connect one of the connectors on the optical drive power cable to the tape drive If however you are installing an RDX internal USB tape drive you will need to install the SATA to traditional powe...

Страница 267: ...ugh the plastic slots on the bottom of the chassis underneath the fan cage assembly For more information see Internal cable routing and connectors 7 Close the bezel 8 Install and lock the left side co...

Страница 268: ...affle on page 212 9 Remove the fan cage assembly see Removing the fan cage assembly on page 243 10 Disconnect the light path diagnostics cable from the system board see System board internal connector...

Страница 269: ...SB cable away from the mounting bracket 16 If you are instructed to return the USB cable and light path diagnostics assembly follow all packaging instructions and use any packaging materials for shipp...

Страница 270: ...the opening in the front of the server 4 Position the bottom of the USB cable and light path diagnostics assembly mounting bracket into the opening and rotate the top of the bracket toward the server...

Страница 271: ...12 Reconnect the external cables and power cords then turn on the attached devices and turn on the server Chapter 5 Removing and replacing server components 253...

Страница 272: ...ower supply or power supplies from the power supply cage see Removing a hot swap power supply on page 273 7 Rotate the power supply cage to its open position see Opening the power supply cage on page...

Страница 273: ...on page 254 to remove the remaining backplane 13 If you are instructed to return the 2 5 inch hard disk drive backplane follow all packaging instructions and use any packaging materials for shipping...

Страница 274: ...age 164 4 If you are replacing another 2 5 inch hard disk drive backplane repeat steps 1 through 3 to install the additional backplane 5 Install the hot swap hard disk drives see Installing a 2 5 inch...

Страница 275: ...side cover on page 181 4 Open the bezel 5 Remove the fan cage assembly see Removing the fan cage assembly on page 243 6 Remove the hot swap hard disk drives that are installed in the hard disk drive c...

Страница 276: ...lane 12 Lift up on the spring release latch on the drive cage and rotate the backplane away from the drive cage until the backplane tab disengages from the drive cage 13 If you are instructed to retur...

Страница 277: ...nfiguration and signal cables to the 3 5 inch hard disk drive backplane For more information see Internal cable routing and connectors 4 Install the hot swap hard disk drives that were removed from th...

Страница 278: ...alling the left side cover on page 181 10 Lock the left side cover 11 Reconnect the external cables and power cords then turn on the attached devices and turn on the server 260 IBM System x3400 M3 Typ...

Страница 279: ...the fan cage assembly see Removing the fan cage assembly on page 243 6 Remove the simple swap hard disk drives that are installed in the hard disk drive cage see Removing a simple swap hard disk drive...

Страница 280: ...drive backplane 12 Lift the latch and rotate the simple swap backplate away from the drive cage as shown in the illustration 13 Remove the simple swap backplate and set it aside 14 If you are instruct...

Страница 281: ...ration and signal cables to the 3 5 inch hard disk drive backplate For more information see Internal cable routing and connectors 4 Install the simple swap hard disk drives that were removed from the...

Страница 282: ...alling the left side cover on page 181 10 Lock the left side cover 11 Reconnect the external cables and power cords then turn on the attached devices and turn on the server 264 IBM System x3400 M3 Typ...

Страница 283: ...ly cage see Removing a hot swap power supply on page 273 6 Rotate the power supply cage to its open position see Opening the power supply cage on page 154 7 Remove the air baffle see Removing the air...

Страница 284: ...isk drive backplane on page 254 14 If you are instructed to return the 2 5 inch disk drive cage follow all packaging instructions and use any packaging materials for shipping that are supplied to you...

Страница 285: ...el 6 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to fall over 7 Connect the power and signal cables from the system board...

Страница 286: ...the cover facing up Attention Do not allow the server to fall over 4 Unlock and remove the left side cover see Removing the left side cover on page 181 5 Remove the power supply or power supplies from...

Страница 287: ...e screws for future use 14 Pull the drive cage out of the front of server 15 Remove the UltraSlim DVD drive if installed 16 Remove the backplane from the 3 5 inch disk drive cage see Removing the 3 5...

Страница 288: ...ive in to the slim slot on top of the upper 3 5 inch disk drive cage follow steps from 2 on page 206 to 2o on page 210 6 Install the 3 5 inch disk drive backplane in the back of the drive cage see Ins...

Страница 289: ...e 3 5 inch disk drive backplane and UltraSlim DVD drive see Hard disk drive backplane connectors on page 20 and Internal cable routing and connectors on page 164 14 Install the fan cage assembly see I...

Страница 290: ...urface to ease removal 2 Press in on the clips that hold the feet in place then pry the feet away from the server In some cases you might need a screwdriver to press in on the clips Feet 3 Reinstall t...

Страница 291: ...server you must turn off the server before removing the power supply To remove a hot swap power supply complete the following steps 1 Read the safety information that begins on page vii and Handling s...

Страница 292: ...following precautions Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any...

Страница 293: ...e Note If only one hot swap power supply is installed in the server a power supply filler must be installed in the empty power bay 5 Connect one end of the power cord for the new power supply into the...

Страница 294: ...om the power supply cage see Removing a hot swap power supply on page 273 4 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to...

Страница 295: ...ect the power supply cage cables from the system board 10 Return the power supply cage to its closed position see Closing the power supply cage on page 156 11 Remove the three screws on the rear of th...

Страница 296: ...then remove the power supply cage from the package 2 Position the hinge so that the power supply cage would be in the open position if it were installed in the server 3 Move the hinge inside the serve...

Страница 297: ...he cables to the system board see System board internal connectors on page 15 b Place the power cable shield over the power cables and align the locating tabs on the cable shield with the correspondin...

Страница 298: ...7 Return the power supply cage to its closed position see Closing the power supply cage on page 156 8 Install the power supplies see Installing a hot swap power supply on page 274 9 Install and lock t...

Страница 299: ...it is lying flat with the cover facing up Attention Do not allow the server to fall over 4 Unlock and remove the left side cover see Removing the left side cover on page 181 5 Remove any adapters that...

Страница 300: ...extender card out of the system board connector 9 If you are instructed to return the extender card follow all packaging instructions and use any packaging materials for shipping that are supplied to...

Страница 301: ...ard into the connector 3 Install the two screws that secure the extender card to the system board tray 4 Install the system board in the server see Installing the system board on page 298 5 Install an...

Страница 302: ...ply cage to its open position see Opening the power supply cage on page 154 7 Remove the air baffle see Removing the air baffle on page 212 8 Remove the microprocessor heat sink a Lift the heat sink r...

Страница 303: ...r socket 2 a Open the retaining clips on each end of the VRM connector b Pull the VRM out of the connector 11 If you are instructed to return the microprocessor follow all packaging instructions and u...

Страница 304: ...4 Click System x3400 M3 to display the matrix of downloadable files for the server v Optional Obtain an SMP capable operating system For a list of supported operating systems and optional devices see...

Страница 305: ...the microprocessor bracket frame and remove the microprocessor filler if one is installed Attention a Do not touch the microprocessor contacts handle the microprocessor by the edges only Contaminants...

Страница 306: ...et The microprocessor has two notches that are keyed to two tabs on the sides of the socket A triangle shaped indicator on one corner of the microprocessor points to a 45 degree angle on one corner of...

Страница 307: ...er from the bottom of the heat sink if one is installed c Position the heat sink above the microprocessor with the thermal grease side down Attention The heat sink is keyed to the retention module Mak...

Страница 308: ...ctor Firmly press the VRM straight down into the connector by applying pressure on both ends of the VRM simultaneously The retaining clips snap into the locked position when the VRM is seated in the c...

Страница 309: ...emoved 4 Use a clean area of the cleaning pad to wipe the thermal grease from the microprocessor then dispose of the cleaning pad after all of the thermal grease is removed Microprocessor 0 02 mL of t...

Страница 310: ...ply or power supplies from the power supply cage see Removing a hot swap power supply on page 273 6 Rotate the power supply cage to its open position see Opening the power supply cage on page 154 7 Re...

Страница 311: ...n page 286 Attention Make sure that you install each heat sink with its paired microprocessor 4 Install the air baffle see Installing the air baffle on page 213 5 Return the power supply cage to its c...

Страница 312: ...rom the power supply cage see Removing a hot swap power supply on page 273 6 Rotate the power supply cage to its open position see Opening the power supply cage on page 154 7 Remove the air baffle see...

Страница 313: ...and heat sink see Installing a microprocessor and heat sink on page 286 Attention Make sure that you install each heat sink with its paired microprocessor 4 Install the air baffle see Installing the...

Страница 314: ...y on page 273 6 Rotate the power supply cage to its open position see Opening the power supply cage on page 154 7 Remove the air baffle see Removing the air baffle on page 212 8 Remove the fan cage as...

Страница 315: ...r to disengage the tabs from the chassis then grasp the handles and carefully lift the system board out of the server Attention When you lift the system board out of the server being careful neither t...

Страница 316: ...rear of the chassis to secure the system board 4 Install any of the following components that you removed from the system board v Microprocessors and heat sinks see Installing a microprocessor and hea...

Страница 317: ...osed position see Closing the power supply cage on page 156 9 Install the power supplies see Installing a hot swap power supply on page 274 10 Install and lock the left side cover see Installing the l...

Страница 318: ...300 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 319: ...rmation about using the IMM see Using the integrated management module on page 311 v VMware ESXi embedded hypervisor The VMware ESXi embedded hypervisor is available on the server models that come wit...

Страница 320: ...o modify UEFI settings from the command line without the need to restart the server to access the Setup utility For more information about using this program see IBM Advanced Settings Utility on page...

Страница 321: ...Resolve configuration conflicts Starting the Setup utility To start the Setup utility complete the following steps 1 Turn on the server Note Approximately 20 seconds after the server is connected to A...

Страница 322: ...rated Ethernet controllers the SAS SATA adapter SATA optical drive channels and PCI slots If you disable a device it cannot be configured and the operating system will not be able to detect it this is...

Страница 323: ...starts from the first boot record that it finds This choice is on the full Setup utility menu only v Boot Manager Select this choice to view add or change the device boot priority boot from a file se...

Страница 324: ...t you have made in the settings and restore the previous settings v Load Default Settings Select this choice to cancel the changes that you have made in the settings and restore the factory settings v...

Страница 325: ...there is no way to change override or remove it You must replace the system board v Change the position of the power on password switch enable switch 2 of the system board switch block SW6 to bypass t...

Страница 326: ...irmware becomes damaged use this backup copy To force the server to start from the backup copy turn off the server then place the UEFI boot recovery jumper JP6 in the backup position pins 2 and 3 Use...

Страница 327: ...m the CD v Detects installed optional hardware devices and provides updated device drivers for most adapters and devices v Provides diskette free installation for supported Windows operating systems v...

Страница 328: ...system partition options that are based on your operating system selection and the installed hard disk drives 4 The ServerGuide program prompts you to insert your operating system CD and restart the s...

Страница 329: ...SNMP e mail v Auto Boot Failure Recovery v A virtual media key which enables remote presence support remote video remote keyboard mouse and remote storage v Automatic Server Restart ASR when POST is...

Страница 330: ...perform other management functions Any standard Telnet client application can access the SOL connection Using the embedded hypervisor The VMware ESXi embedded hypervisor is available on server models...

Страница 331: ...ssage from the Web interface when you attempt to start the remote presence feature indicating that the hardware key is required to use the remote presence feature The virtual media key has an LED When...

Страница 332: ...ons complete the following steps 1 Open a Web browser on a computer that connects to the server and in the address or URL field type the IP address or host name of the IMM to which you want to connect...

Страница 333: ...umpers or configure the controllers However you must install a device driver to enable the operating system to address the controllers To find updated information about configuring the controllers com...

Страница 334: ...previously stored on the secondary drive of the mirrored pair v If you install a different type of RAID adapter see the documentation that comes with the adapter for information about viewing and cha...

Страница 335: ...or Minus key to select Yes select or No deselect to select or deselect a drive from a RAID disk 5 Continue to select drives using the Spacebar or Minus key until you have selected all the drives for y...

Страница 336: ...k for updates The available updates are displayed in a table 4 Select the updates that you want to install and click Install to start the installation wizard If your management server is not connected...

Страница 337: ...ad the ASU version for your operating system 2 ASU sets the UUID in the Integrated Management Module IMM Select one of the following methods to access the Integrated Management Module IMM to set the U...

Страница 338: ...ine KCS access unauthenticated and user restricted You do not need to specify a value for access_method when you use this access method Example asu set SYSTEM_PROD_DATA SysInfoUUID uuid_value The KCS...

Страница 339: ...e click IBM System x and BladeCenter Tools Center then click Tool reference for the available tools 5 Restart the server Updating the DMI SMBIOS data The Desktop Management Interface DMI must be updat...

Страница 340: ...g commands to set the DMI asu set SYSTEM_PROD_DATA SysInfoProdName m t_model access_method asu set SYSTEM_PROD_DATA SysInfoSerialNum s n access_method asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset...

Страница 341: ...method requires that the IPMI driver be installed Some operating systems have the IPMI driver installed by default ASU provides the corresponding mapping layer The following commands are examples of...

Страница 342: ...odel host imm_ip asu set SYSTEM_PROD_DATA SysInfoSerialNum s n host imm_ip asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip v Bootable media You can also build a bootable media using...

Страница 343: ...gnostic tests that you can perform Most systems operating systems and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes If yo...

Страница 344: ...and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through your IBM reseller or IBM Services To locate a reseller authorized by IBM to provide...

Страница 345: ...FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include techn...

Страница 346: ...e KB stands for 1024 bytes MB stands for 1 048 576 bytes and GB stands for 1 073 741 824 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB...

Страница 347: ...Limits Particulate v The room air must be continuously filtered with 40 atmospheric dust spot efficiency MERV 9 according to ASHRAE Standard 52 21 v Air that enters a data center must be filtered to 9...

Страница 348: ...dio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Prop...

Страница 349: ...kt entspricht den Schutzanforderungen der EU Richtlinie 2004 108 EG zur Angleichung der Rechtsvorschriften ber die elektromagnetische Vertr glichkeit in den EU Mitgliedsstaaten und h lt die Grenzwerte...

Страница 350: ...en Germany Telephone 49 7032 15 2937 Email tjahn de ibm com Generelle Informationen Das Ger t erf llt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A VCCI Class A statement This is a Class...

Страница 351: ...Russia Electromagnetic Interference EMI Class A statement People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix B Notices 333...

Страница 352: ...334 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 353: ...rview 313 boot selection menu program using 308 C cable routing internal 164 cache 7 caution statements 6 checkout procedure 73 74 Class A electronic emission notice 330 closing power supply cage 156...

Страница 354: ...ages 98 DVD cable routing 167 drive problems 75 drive installing 203 drive removing 199 error symptoms 75 DVD drive activity LED 10 eject button 10 E eject button DVD 10 electrical input 9 electronic...

Страница 355: ...hot swap SAS or SATA removing 190 hardware service and support 326 heat output 9 heat sink retention module installing 293 removing 292 help getting 325 hot swap drives SAS backplane LEDs 10 SAS SATA...

Страница 356: ...gs system event message 37 LSI Configuration Utility overview 315 starting 316 M memory 7 installing 226 two DIMM per channel 2DPC 232 234 memory mirroring description 228 DIMM population sequence 229...

Страница 357: ...flash device 77 IMM 37 intermittent 78 memory 80 microprocessor 82 monitor 83 mouse 78 optional devices 85 POST 26 power 86 137 serial port 87 ServerGuide 88 software 89 undetermined 138 USB port 89 p...

Страница 358: ...alling 263 removing 261 size 8 slots 7 software problems 89 software service and support 326 stabilizing feet turning 272 starting backup server firmware 308 LSI Configuration Utility 316 Setup utilit...

Страница 359: ...ure 313 ServerGuide 308 Setup utility 303 the remote presence feature 313 V video connector 11 problems 83 viewing event logs 24 virtual media key installing 226 removing 225 VMware Hypervisor support...

Страница 360: ...342 IBM System x3400 M3 Types 7378 and 7379 Problem Determination and Service Guide...

Страница 361: ......

Страница 362: ...Part Number 00KC028 Printed in USA 1P P N 00KC028...

Отзывы: