Service Guide
D-18
Error
Number
Source
Failing
Function
Codes
Failure
Percent
(%)
Description
403-074
K
B94
B96 or
B97
50
50
Description: Error correction code mechanism.
Multiple Error generation error.
Action: Use MAP 0210.
403–075
K
B94
C64
D28
B96
B97
D33
50
50
50
50
50
50
Description: DCB or SMC error.
Multiple Error generation error.
Action: Use MAP 0210.
403-080
K
B94
B96 or
B97
50
50
Description: Main Memory refresh mechanism.
Main memory read error.
Action: Use MAP 0210.
403-081
K
B94
B96 or
B97
50
50
Description: Main Memory refresh mechanism.
Main memory refresh error.
Action: Use MAP 0210.
403-090
K
B94
B96 or
B97
50
50
Description: Main Memory Full test.
Phase number i error.
Action: Use MAP 0210.
403-100
K
B48
C61
C62
C63
C65
40
30
30
30
30
Description: ECC Data lines accessibility error. Write all 0 and 1
error.
Action: Use MAP 0210.
403-101
K
B48
C61
C62
C63
C65
40
30
30
30
30
Description: ECC Data lines accessibility error. Walking 1 among
0 error.
Action: Use MAP 0210.
403-102
K
B48
C61
C62
C63
C65
40
30
30
30
30
Description: ECC Data lines accessibility error. Walking 0 among
1 error.
Action: Use MAP 0210.
403-103
K
B48
C61
C62
C63
C65
40
30
30
30
30
Description: ECC Data lines accessibility error. RAM bus error.
Action: Use MAP 0210.
403-500
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IOD-HW-STS error, bit i#1.
Action: Use MAP 0210.
403-501
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IOD-HW-STS error, bit i#0.
Action: Use MAP 0210.
403-502
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
CPU error.
Action: Use MAP 0210.
403-505
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
MIR register error.
Action: Use MAP 0210.
Содержание 7015-R30
Страница 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 34: ...1 20 Service Guide...
Страница 206: ...6 2 Service Guide Detail 1 Front Bezel Front Access Plate and CPU Enclosure 1 2 3 4 5 10 11 12 6 10 11 12 9 7 8...
Страница 210: ...6 6 Service Guide Detail 3 Media Module 1 21 22 2 3 7 6 5 4 13 9 8 20 16 14 10 15 17 11 18 23 24 19 12...
Страница 212: ...6 8 Service Guide Detail 4 CPU Module 1 of 3 17 18 19 3 12 1 2 5 6 4 7 20 21 22 14 8 9 10 16 15 24 25 11 13 23...
Страница 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Страница 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Страница 252: ...B 8 Installation and Service Guide...
Страница 288: ...Service Guide D 30...
Страница 299: ......
Страница 300: ...Printed in the U S A SA23 2743 02 40H7126...