3.1 Basic Operation
62
[Basic Operation Procedures]
[1] Establish the parameter settings on all the connected axes by using a teaching tool such
as the PC software.
1) When using an operation pattern in those described in the next page except for
Remote I/O Mode, set the Parameter No. 25 PIO Pattern to 8. When using
Remote I/O Mode
(Note 1)
, establish the setting in Parameter No. 25 PIO Pattern
considering the suitable operation mode to be used.
[Refer to 3.4.10 Control Signals in Remote I/O Mode.]
Note 1: It is necessary to set all the axes of MSCON to Remote I/O Mode.
2) Set the zone (Parameters No.1 and 2) and soft limit (Parameter No.3 and 4) that
suit to the system.
[Refer to Chapter 7 Parameter Setting]
[2] Initial Setting [Refer to Sections 3.2 and 3.9]
Establish the settings for those such as the slave addresses in the field network using
Gateway Parameter Setting Tool. Establish the settings of the motions for all the axes.
1) Establish the setting following the procedure described in Section 3.2.
2) Set the gateway parameters to suit the system to be used.
Establish such settings as the calendar function (clock setting) use or the speed unit
change in Direct Indication Mode.
[3] Setting of Position Data [Refer to Sections 3.3]
(Note) Setting of Direct Indication Mode is not necessary.
Set the data for those to be used such as target position, speed, etc. to the position data.
[4] Field Network Settings [Refer to Sections 3.4.1 and 3.4.2]
Assign MSCON to PLC (master unit).
[Refer to the instruction manuals for the master unit and PLC]
[5] Link to Network
1) Put the operation mode setting switch on the front panel of MSCON to AUTO side and
reboot the power. (By putting to AUTO, field network line activates.)
2) Once the link to PLC (master unit) is established
(Note 2)
, turn ON MON Signal of the
gateway control signals
(Note 3)
. While MON Signal is ON, control from field network is
available.
Note 2: By referring to 3.10 Field network status LEDs display, confirm that the
communication is established in the normal condition.
Note 3: Refer to 3.4.3 Control Signals of Gateway.
[6] Operation Control in Each Operation Mode [Refer to Sections 3.4.4 to 3.4.10]
1) Send the information of the target position, speed, acceleration/deceleration, etc. from
PLC (master unit) to the MSCON.
2) The actuator follows the received information of the target position, speed,
acceleration/deceleration, etc. to perform a positioning at the specific coordinates.
3) Confirm the status of positioning complete.
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......