3.8 C
ontrol and functions of Input and output signals of Remote I/O Mode
205
Caution: (1) The speed during tension operation is set in Parameter No.34. [Refer to
9.1 List of Specifications of Connectable Actuators for the pressing speed.]
Do not set any value larger than the value in the list. If the speed set in the
position table is equal to or less than the tension speed, the tension
operation is performed at the setup speed.
(2) The tension ready position should be the tension start position or forward. If
not, the moving direction varies depending on the start position to be
dangerous.
The tension operation from a coordinate (less than 30mm = 80 – 50 in the
above example) located before the end position (30mm or less) changes to
the pressing operation from the current position to the tension end position.
Note that the tension operation after positioning to the position of 80mm
does not take place.
(3) The work is pulled also after completion of the tension. The work is drawn
back or pulled further if the work is moved. When the work is drawn back
before the approach position, alarm code 0DC “pressing operation range
error” occurs to stop the work. When the work is moved in the tension
direction and the load current becomes less than the current limit value
(pressing in [%]), PEND is turned OFF. Naturally, the work reaches the
tension moving distance set in “Positioning width” to cause miss-pressing.
(4) Tension operation cannot be performed with the rotary actuator.
Pressing Operation
ST*: Start position
ST*
ST*
ST*
Tension Operation
Approach Operation
Tension Operation
Tension start position
80mm
Tension end position
80 – 50 = 30mm
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......