Chapter 7 Parameter
251
Parameter List (continued)
No.
Category
Name Symbol Unit
(Note 1)
Input Range
Default factory
setting
Relevant
sections
105 C
Damping
Characteristic
Coefficient 1
DC11
-
0 to 1000
10
4.2
106 C
Damping
Characteristic
Coefficient 2
DC21
-
0 to 1000
1000
4.2
107 B
Natural Frequency
NP01
1/1000Hz
500 to 30000
10000
4.2
108 C
Vi
bration
suppre
ss
paramete
r s
et
3
Notch Filter Gain
NFG2
-
1 to 20000
9990
4.2
109 B Default Vibration Suppress
No.
CTLF
-
0 to 3
0
4.2
110 B Stop Method at Servo OFF
FSTP
-
0: Rapid stop
1: Deceleration to
stop
0
4.2
112 B Monitoring Mode Selection
FMNT
-
0: Unused
1: Monitor
Function 1
2: Monitor
Function 2
3: Monitor
Function 3
1
7.2 [59]
113 B Monitoring Period
FMNT
msec
1 to 100
1
7.2 [60]
117 B Automatic Loadcell
Calibration at Start
FFRC
118 B
Pressing Operation without
Completion of Loadcell
Calibration
FFRC
119 B Loadcell Calibration Time
CLBT
For future
extension use.
Unavailable
120 C Servo Gain Number 1
PLG1
-
0 to 31
In accordance
with actuator
(Note 2)
7.2 [5]
7.3
121 C Feed Forward Gain 1
PLF1
-
0 to 100
In accordance
with actuator
(Note 2)
7.2 [41]
122 C Velocity Loop Proportional
Gain 1
VLG1
-
1 to 27661
In accordance
with actuator
(Note 2)
7.2 [21]
7.3
123 C Velocity Loop Integral Gain 1
VLT1
-
1 to 217270
In accordance
with actuator
(Note 2)
7.2 [22]
7.3
124 C Torque Filter Time Constant 1
TRF1
-
0 to 2500
In accordance
with actuator
(Note 2)
7.2 [23]
7.3
125 C Current Control Width
Number 1
CLP1
0 to 4
In accordance
with actuator
(Note 2)
7.2 [35]
7.3
126 C Servo Gain Number 2
PLG2
-
0 to 31
In accordance
with actuator
(Note 2)
7.2 [5]
7.3
127 C Feed Forward Gain 2
PLF2
-
0 to 100
In accordance
with actuator
(Note 2)
7.2 [41]
128 C Speed Loop Proportional
Gain 2
VLG2
-
1 to 27661
In accordance
with actuator
(Note 2)
7.2 [21]
7.3
129 C Speed Loop Integral Gain 2
VLT2
-
1 to 217270
In accordance
with actuator
(Note 2)
7.2 [22]
7.3
130 C Torque Filter Time Constant 2
TRF2
-
0 to 2500
In accordance
with actuator
(Note 2)
7.2 [23]
7.3
Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the
parameters are set in accordance with the specification.
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......