Chapter 7 Parameter
265
[29] Velocity override (Parameter No.46)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
46 Velocity Override
OVRD
%
1 to 100
100
When move commands are issued from the PLC, the moving speed set in the “Velocity” field of
the position table can be overridden by the value set by this parameter.
Actual movement velocity = [Velocity set in the position table] × [setting value in Parameter
No.46]
Example) Value in the “Velocity” field of the position table: 500mm/s
Setting in Parameter No.46 20%
In this case, the actual movement speed becomes 100mm/s.
The minimum setting unit is 1% and the input range is 1 to 100%.
Note: This parameter is ignored for move commands from a teaching tool such as PC
software.
[30] PIO jog velocity 2 (Parameter No.47)
Refer to Section 7.2 [19] for details.
[31] PIO inch distance, PIO inch distance 2 (Parameter No.48, No.49)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
48
PIO Inching Distance
IOID
mm
[deg/s]
0.01 to 1.00
0.1
49
(Note 1)
PIO Inching Distance 2
IOD2
mm
[deg/s]
0.01 to 1.00
0.1
When the selected PIO pattern is “1” (teaching mode), this parameter defines the inching
distance to be applied when inching input commands are received from the PLC.
The maximum allowable value is 1 mm.
Note 1: Parameter No.49 “PIO inching distance 2” is not used for the controller.
[32] Load output judgment time period (Parameter No.50)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
50 Load Output Judgment Time
Period
LDWT
msec
0 to 9999
255
This parameter defines the time taken to judging whether torque level status signal (TRQS) is
ON.
If the command torque exceeds the value set in “Threshold” of position data for the time set by
this parameter during pressing operation, torque level status signal (TRQS) is turned ON.
Refer to 3.8.2 [4] or 3.8.3 [3] Pressing Operation for the details of the pressing operation.
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......