Chapter 1 Specifications Check
24
1.2 Basic Specifications
Item
Description
Number of Controlled Axes
Max. 6-axis
Control Power Voltage
24V DC
±
10%
Control Power Current Consumption
Max. 2.4A
Add the Control Power In Rush Current
(Note1)
Max. 7A 5msec or less
Driving Source Voltage
100V AC Specification AC100 to 115V
±
10%
Drive (Motor)
Power Supply
Voltage
Driving Source Voltage
200V AC Specification AC200 to 230V
±
10%
Driving Source Voltage
100V AC Specification
10A max. with 20A for 80msec
(driving source voltage 100V in ambient temp. 25
°
C)
10A max. with 45A for 80msec
(driving source voltage 115V × 10% in ambient temp. 40
°
C)
Drive (Motor)
Power Supply
In-Rush Current
(Note1)
Driving Source Voltage
200V AC Specification
10A max. with 45A for 40msec
(driving source voltage 200V in ambient temp. 25
°
C)
10A max. with 95A for 40msec
(driving source voltage 230V × 10% in ambient temp. 40
°
C)
Driving Source Voltage
100V AC Specification Max. 200W/axis (up to 450W in total for six axes)
Motor Capacity of
Connectable
Actuators
Driving Source Voltage
200V AC Specification Max. 200W/axis (up to 900W in total for six axes)
Electromagnetic Brake Power Supply
Voltage
(when brake-equipped actuator
connected)
24V DC
±
10%
Brake Power Supply Current
Max. 1A/axis (0.5A/axis at steady state)
Brake Power Supply In-Rush Current
(Note1)
Max. 10A 10msec or less
Drive (Motor) Power Capacity
Refer to 1.3.1 Power Capacity and Heat Generation.
Leak Current
3.5mA (Motor power supply)
◎
There is no leak current of control power supply and brake power supply.
Heat Generation
Refer to 1.3.1 Power Capacity and Heat Generation.
Drive (Motor) Frequency
50/60Hz
±
5%
Transient Power Cutoff Durability
1msec (Control Power Supply), 20msec (Drive (Motor) Power Supply), 5msec
(Brake Power Supply)
Motor Control System
Sinusoidal Wave PWM Vector Current Control
Applicable Encoder
Incremental Serial Encoder, Battery-less Absolute Encoder,
Absolute Serial Encoder
Actuator Cable Length
Max. 20m
Serial Communication
(SIO Port: For Teaching)
RS485 1ch (complying with Modbus Protocol) Speed : 9.6 to 230.4kbps
External Interface
DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, EtherNet/IP, EtherCAT
[Refer to Section 1.4. Fieldbus Type]
Data Setting and Input
PC software, Teaching pendant, Gateway parameter setting tool
Data Retention Memory
Position data and parameters are saved in the nonvolatile memory.
(There is no limitation in number of writing)
Number of Positioning Points
Max. 256 points (There is no limit for simple direct and direct indication modes)
Note:
The number of positioning points differs depending on the operation mode
select by the parameter setting.
LED Indication (Mounted on Front Panel) LED lamp for driver status display 2 points, Gateway Status LED 5 points,
Fieldbus Status LED 2 points, Power Supply Status LED 2 points
Forcibly Releasing of Electromagnetic
Brake (Mounted on Front Panel)
Switching NOM (standard)/RLS (compulsory release)
Protective Functions
Overload, overcurrent, overvoltage, etc.
Protection Function against Electric Shock Class I
Insulation Resistance (Between
secondary power source and FG)
500V DC 10M
Ω
or more
Withstanding Voltage (Between primary
and secondary power sources, Between
primary power source and PE)
1500V AC for 1 min.
(for MSCON individually)
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......