Chapter 2 Wiring
57
2) CC-Link Type
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
CC-Link Connector Model
Remarks
Cable Side
SMSTB2.5/5-ST-5.08 AU Enclosed in standard
package
Manufactured by PHOENIX
CONTACT
Controller Side
MSTBA2.5/5-G-5.08 AU
Pin No. Signal Name
(Color)
Contents
Applicable
Cable
1
DA (BL)
Communications Line A
2
DB (WT)
Communications Line B
3
DG (YW)
Digital GND
4
SLD
Connect the shield of the shielded
cable (Connect the FG of the 5 pins
and controller FG internally)
5 FG
Frame Ground
(Connect the SLD of the 4 pins and
controller FG internally)
CC-Link
Dedicated
Cable
(Note): Connect a terminal resistor (121
Ω
) between DA and DB to the
end of the network. [Refer to 2.2 [8] Field network Circuit (For
Field network Type)]
Front view of
connector on
controller side
DA
DB
SLD
FG
DG
ME0306-2A