Chapter
8 T
roubleshooting
294
Alarm
Code
Alarm
Level
Alarm Name
Cause/Treatment
0A3
Position command
data error
Cause
: 1) The command value during direct numeric
specification exceeded the maximum set value.
2) Pressing operation was specified in the field
bus specification while the vibration suppress
function remained effective.
Treatment : 1) Exceeded command item code is displayed in
the detailed code. Input an appropriate value
by referring to these values.
Detailed Code
(Command Item Code)
Command Item
0F00
Target Position
0F02
Command Speed
0F04
Acceleration
0F06
Deceleration
0F08
Positioning Width
0F0C
Pressing Current
Limit Value
0F0D
Control Signal
2) The vibration suppress control function and
pressing operation cannot be used
concurrently. Provide setting so that either of
the functions is effective.
0A5
Operation
release
Electromagnetic brake
unreleased error
Cause
: The brake cannot be released.
Treatment : Supplied the 24V power unit for the
electromagnetic brake.
0A6
Cold start
Dynamic brake not
released
Cause
: The dynamic brake cannot be released when the
servo is ON due to noise and electrostatic, etc.
Treatment : Implement measures to eliminate noise or
electrostatic. There is a concern of circuit
breakdown. Please contact IAI.
0A7
Operation
release
Command
deceleration error
Cause
: Even though the deceleration setting was
changed lower during a movement, because there
is not enough deceleration distance for the
deceleration from the current position, the
actuator exceeded the soft limit.
Deceleration starting position
not resulting in soft limit overshoot
If a command is issued here,
soft limit overshoot will occur
Soft limit
Treatment : Make the timing earlier for the movement
command for the deceleration speed change.
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......