56 S-motion Rate
SCRV
%
0 to 100
0
This parameter is used when the value in the “Acceleration/deceleration mode” field of the
position table is set to “1 (S-motion)”.
This enables to ease the impact at acceleration and deceleration without making the takt time
longer.
The S-motion is a sine curve that has the acceleration time as 1 cycle.
The level of its swing width can be set by this parameter.
Setting of Parameter No.56 [%] Level of swing width
0 [Set in delivery]
No S-motion (Dotted line shown in the image below)
100
Sine curve swing width × 1 (Double-dashed line shown in the image below)
50
Sine curve swing width × 0.5 (Dashed line shown in the image below)
10
Sine curve swing width × 0.1 (Solid line shown in the image below)
Velocity
Time
0
Setting: 10
Setting: 50
Setting: 100
Within 2 seconds
(Caution 3))
Caution:
1) If the S-motion is specified in acceleration/deceleration mode, executing position
command or direct value command while the actuator is moving causes an actuator to
move along the trapezoid pattern.
To change a speed during operation, be sure to specify such a position command
while the actuator is in pause state.
2) In the index mode of rotary actuator, the S-motion control is disabled. If S-motion
acceleration/deceleration is specified, the trapezoid pattern is used in
acceleration/deceleration mode.
3) If acceleration time or deceleration time exceeds 2 seconds, do not specify S-motion
control. The actuator will be the trapezoid operation.
4) Do not perform temporary stop during acceleration or deceleration. The speed change
(acceleration) may cause the dangerous situation.
Velocity
Time
Swing width
Acceleration time
0
ME0306-2A
Содержание MSCON
Страница 1: ...MSCON Controller Instruction Manual Second Edition ...
Страница 2: ......
Страница 4: ...ME0306 2A ...
Страница 8: ...ME0306 2A ...
Страница 20: ...12 ME0306 2A ...
Страница 28: ...20 ME0306 2A ...
Страница 46: ...Chapter 1 Specifications Check 38 ME0306 2A ...
Страница 240: ...3 11 Gateway status LED 232 ME0306 2A ...
Страница 246: ...Chapter 4 Vibration Suppress Control Function 238 ME0306 2A ...
Страница 290: ...Chapter 7 Parameter 282 ME0306 2A ...
Страница 310: ...Chapter 8 Troubleshooting 302 ME0306 2A ...
Страница 354: ...Chapter 9 Appendix 346 ME0306 2A ...
Страница 358: ......
Страница 359: ......