ArcGlide THC
Instruction Manual
2-39
INStALLAtIoN
Part number
Length
223212
3.0 m (10 ft)
2232222
6.0 m (20 ft)
223119
7.5 m (25 ft)
223223
10.5 m (35 ft)
223008
15.0 m (50 ft)
223099
23.0 m (75 ft)
223100
30.5 m (100 ft)
223101
45.5 m (150 ft)
223102
61.0 m (200 ft)
Pin number*
Signal name
1
TX + (transmit data +)
2
TX – (transmit data –)
3
RX + (receive data +)
4
Not connected
5
Not connected
6
RX – (receive data –)
7
Not connected
8
Not connected
Hypernet and HMI interface cable
Connect this end to the
ArcGlide HMI.
Connect this end to
the control module
or Ethernet switch.
In a Hypernet or mixed configuration where there is more
than one Hypernet span, use these cables to connect the
components of the system to the Ethernet switch.
If you use Ethernet cable from another supplier, verify that
the cable is a standard, shielded RJ-45 Cat-5e cable.
* Pin numbers are the same on both ends of the cable.