ArcGlide THC
Instruction Manual
3-29
oPeRAtIoN
Phoenix parameter
Description
Retry on transfer fail
Description:
This value determines the number of times that the CNC will attempt to re-start the plasma
after failing to transfer. The CNC removes and reapplies the start signal on each re-start
attempt. Set this parameter to 0 to disable this feature.
Setting:
0 – 5
transfer time
Description:
This is the number of seconds that the CNC will wait for transfer before attempting a retry.
If Retry on Transfer Fail is disabled (set to 0), this setting has no effect.
Setting:
0 – 5 seconds
Use Pierce Complete
Description:
This signal is used with HPR plasma systems to change the gas flow during the pierce.
Generally, this setting is active for all O
2
-Air and O
2
-O
2
processes.
Setting:
OFF / ON
Puddle Jump Height
Description:
This value determines the height above the workpiece that the torch is raised to clear the
top dross puddle that can form during the pierce. It is the torch height after Pierce. This
height is entered as a percentage of the Cut Height. The torch remains at this height until
the Cut Height Delay has elapsed. If this feature is not used, set this parameter to 100%.
Setting:
50% – 500% of Cut Height
Creep time
Description:
This is the number of seconds that cutting motion is at a lower speed than the specified
Cut Speed. During this period, the CNC Creep Speed is used. The CNC Creep speed is
set on the CNC Speeds screen as a percentage of the Cut Speed. This setting can help
improve the initial plasma arc stability, especially on thick materials. Set this parameter to 0
to disable this feature.
Setting:
0 – 10 Sec
Cut Height Delay
Description:
This value sets the number of seconds to hold the torch at the Puddle Jump Height before
transitioning to the Cut Height. This time is used to allow the torch to clear the top dross
puddle that forms during a pierce. If this feature is not used, set this parameter to 0.
Setting:
0 – 10 seconds
Содержание ArcGlide Torch Height Control
Страница 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Страница 2: ......
Страница 16: ...English Hypertherm Safety and Compliance S 8...
Страница 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Страница 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Страница 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Страница 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Страница 207: ......
Страница 208: ......