2-40
ArcGlide THC
Instruction Manual
INStALLAtIoN
2
Notes:
• Input signals (pins 2 – 6) use 24 VDC; Output signals (pins
8 – 14) use dry contact closures at 24 VDC.
• For more information about discrete operator console I/O
signals, see
ArcGlide discrete interface signals
.
* Pin numbers are the same on both ends of the cable.
Part number
Length
223216
3.0 m (10 ft)
223217
6.0 m (20 ft)
223121
7.5 m (25 ft)
223218
10.5 m (35 ft)
223006
15.0 m (50 ft)
223111
23.0 m (75 ft)
223112
30.5 m (100 ft)
223113
45.5 m (150 ft)
223114
61.0 m (200 ft)
operator console I/o cable
Green band
Connect this end to
the connector on the
control module with
the green circle.
Add the appropriate
connector for your
console on this end.
Contact your console
supplier for additional
information.
Pin number* Color
Signal name
Dry contact circuit
1
Black
Not connected
2
White
Manual disable switch input +
3
Red
Manual select switch input +
4
Green
Torch up switch input +
5
Orange
Torch down switch input +
6
Blue
Spare switch input +
7
White/black
Common
8
Red/black
Torch enabled output A
9
Green/black
Torch enabled output B
10
Orange/black
Error output A
11
Blue/black
Error output B
12
Black/white
Spare output A
13
Red/white
Spare output B
14
Green/white
Power +24 VDC output
B
A
B
A
B
A
3.9 K
3.9 K
+24 V
A
b
A
b
A
b
+24 V
normally
open
normally
open
normally
open
Содержание ArcGlide Torch Height Control
Страница 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Страница 2: ......
Страница 16: ...English Hypertherm Safety and Compliance S 8...
Страница 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Страница 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Страница 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Страница 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...