ArcGlide THC
Instruction Manual
4-57
MAINteNANCe
2
J3
(Relay contact outputs from the tHC to a
generic plasma system)
Pin number
Signal
1
Corner A
2
Corner B
3
Pierce A
4
Pierce B
5
Hold A
6
Hold B
7
Plasma start A
8
Plasma start B
9
Spare THC out A
10
Spare THC out B
11
Remote on A
12
Remote on B
13
Common
14
Common
15
+24 V output
16
+24 V output
J4 Arc voltage
Pin number
Signal
1
Electrode –
2
Work +
Note: Pins 11 and 12 on connector J3 must be connected to locations 1 and 3 on terminal block 2 in an HPR
plasma system.
Note: The arc voltage terminals on connector J4 must be connected to the I/O board in an HPR plasma system.
Connect the arc
voltage terminals
to the I/o board
in an HPR plasma
system.
J3
Connect pins 11 and 12
to locations 1 and 3 on
terminal block 2 in an
HPR plasma system