2-22
ArcGlide THC
Instruction Manual
ArcGlide plasma interface connection to Powermax G3 series plasma system
ARCGLIDE PLASMA INTERFACE
POWERMAX MACHINE
RELAY
PLASMA START
PULL UP
24V
J2-2
FIELD COMMON
MOTION - RED
START - GRN
INTERFACE CONNECTOR
J2-1
TERMINAL BLOCKS
J3-8
J3-7
MACHINE MOTION
13
14
MOTION - BLK
3
START
START - BLK
4
COMMON
+24V
Rotary address switch,
set to 1.
ArcGlide control module
CNC with Picopath interface
Axes
3, 4
Axes
1, 2
I/o
Rotary address
switch, set to 1
ArcGlide HMI
Arc voltage sense wires. Use
~0.9 mm squared (18 AWG)
twisted pair wire, rated 600 V or
greater
Plasma interface I/o cable
CNC I/o cable
ArcGlide lifter
No connection
Powermax G3
CAt- 5e shielded
ethernet cable
Plasma
interface
(090052),
mounted by
the customer.
Powermax machine interface cable 023206
to Powermax
J15+
to Powermax
J16-
Plasma interface termination
Signal
Wire color
Pin
Plasma Start A
Green
3
Plasma Start B
Black
4
Motion
Red
13
Common
Black
14
Arc voltage
Electrode (-)
~0.9 mm squared (18 AWG)
J16
Work (+)
~0.9 mm squared (18 AWG)
J15
Set dry contacts by
sliding the switch to D.
Lifter interface cable
ArcGlide plasma interface
terminal blocks
Powermax machine
interface connector
electrode (-)
Work (+)
Powermax G3
Plasma Start B
Plasma Start A
Common
Motion
Black
Green
Black
Red
1
1
J2
J3
16
16
2
Содержание ArcGlide Torch Height Control
Страница 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Страница 2: ......
Страница 16: ...English Hypertherm Safety and Compliance S 8...
Страница 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Страница 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Страница 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Страница 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Страница 207: ......
Страница 208: ......