ArcGlide THC
Instruction Manual
3-15
oPeRAtIoN
HMI Parameter Value
Normal errors (continued)
ERR 7 FAILED MOVE TO IHS START
The lifter failed to reach IHS crossover height.
ERR 8 FAILED TO CONTACT PLATE
The torch failed to contact the workpiece
within 60 seconds.
ERR 9 FAILED TO CLEAR PLATE
The torch failed to retract and break Ohmic
contact within 10 seconds.
ERR 10 FAILED TO MOVE TO XFER HT
The torch failed to retract to Transfer Height
within 10 seconds.
ERR 11 IHS SYNC TIMEOUT
The torch reached the IHS position but IHS
SYNC was not released within 60 seconds.
ERR 12 TRANSFER TIMEOUT
The Transfer signal was not received from the
plasma system within 60 seconds.
ERR 13 LOST TRANSFER
The plasma arc was lost during the cut.
ERR 14 FAILED MOVE TO PIERCE
The lifter failed to reach Pierce Start Height
within 10 seconds.
ERR 15 FAILED MOVE CUTHEIGHT
The lifter failed to reach Cut Height during
Accel Delay.
ERR 16 RAMPDOWN TIMEOUT
The Motion signal was not removed within
10 seconds.
ERR 17 RETRACT TIMEOUT
The lifter failed to retract within 20 seconds at
the end of the cut.
ERR 18 ERR SAMPLED ARC VOLTAGE
During sample arc voltage operation, there was
an excessive change in sample voltage.
ERR 19 EXCESS PLATE CONTACT
The torch made excessive contact with the
workpiece.
ERR 20 PLASMA SUPPLY
Plasma system error.
ERR 21 OHMIC TIP SENSE
Ohmic Tip Sense was enabled but not sensed.
Содержание ArcGlide Torch Height Control
Страница 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Страница 2: ......
Страница 16: ...English Hypertherm Safety and Compliance S 8...
Страница 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Страница 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Страница 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Страница 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Страница 207: ......
Страница 208: ......