4-60
ArcGlide THC
Instruction Manual
MAINteNANCe
* The arc voltage terminals on connector J4 must be
connected to the I/O board in the plasma supply.
J4 Arc voltage*
Pin number
Signal
1
Work +
2
Electrode –
J5 CNC interface
Pin number
Signal
1
HPR RX –
2
HPR TX –
3
RS422 Common
4
Motion
5
Error
6
Rampdown error
7
HPR not ready
8
Not connected
9
Not connected
10
Not connected
11
Not connected
12
Spare
13
Pierce A
14
Hold A
15
Start A
16
Not connected
17
Not connected
18
Ground
19
Not connected
20
HPR RX +
21
HPR TX +
22
Not connected
23
Motion
24
Error
25
Rampdown error
26
HPR not ready
27
Not connected
28
Not connected
29
Not connected
30
Not connected
31
Spare
32
Pierce B
33
Hold B
34
Start B
35
Not connected
36
Ground
37
Not connected
J6 Remote oN/off
Pin number
Signal
1
ON/OFF out+
2
ON/OFF out –
2