2-46
ArcGlide THC
Instruction Manual
INStALLAtIoN
Non-serial plasma interface cable
This cable connects the ArcGlide plasma interface PCB and control board inside the plasma system. Use this cable only
when the CNC provides serial communication directly to the control board.
Part number
Length
Used in
223192
61 cm (2 ft)
HPR130 XD, HPR260 XD
223193
2.3 m (7.5 ft)
HPR400 XD
Pin number Color
Signal name
1
Not connected
2
Not connected
3
Not connected
4
Not connected
5
Not connected
6
Black
Motion input +
7
Blue
Motion input –
8
Black
Error input +
9
Yellow
Error input –
10
Black
Rampdown error input +
11
Brown
Rampdown error input –
12
Black
Not ready input +
13
Orange
Not ready input –
14
Black
Spare input +
15
White
Spare input –
red heatshrink