3-20
ArcGlide THC
Instruction Manual
oPeRAtIoN
2
Installation screen
The Installation data display provides information on ArcGlide hardware and software settings that are used by the
control module.
HMI Parameter
Value
Slide Length
This value is the length of the lifter’s usable travel.
Max Servo Current
This is the maximum continuous motor current for which the lifter motor is rated.
Encoder Counts per in This value scales the position feedback.
Maximum Speed
(per min)
This parameter sets the maximum linear speed that the THC can achieve.
Fast Speed (per min)
This speed is used for all automatic rapid moves such as the End-of-Cut-Retract or the
Initial Approach to the workpiece.
Slow Speed (per min)
This speed is the Homing Speed and is the fastest speed used for manual moves. It is also
the maximum speed limit used during arc voltage control.
IHS Speed (per min)
This parameter sets the lowest speed for the final approach to the workpiece during an IHS
operation. It is also used as the low speed for manual moves.
Installation Data
<back>
Slide Length
9.5
Max Servo Current
133.5v