ArcGlide THC
Instruction Manual
1-5
SPeCIfICAtIoNS
2
Specifications
System
Regulatory approvals
CE, CSA
Fused input power (selectable)*
100 to 120 VAC/200 to 240 VAC, 2.6 A/1.5 A,
50/60 Hz, 1 Phase,
Slow blow fuse
250 VAC, 5 A
Parallel digital input range
+12 VDC to +24 VDC
Serial digital I/O
+5 VDC (Plasma interface serial)
Maximum motor drive output
70 VDC, 6 A
Hypernet communication
Shielded RJ-45 Cat-5e
Control module
Control module (090054)
Input power
115 VAC or 230 VAC, 1 Phase, 50/60 Hz
Operating temperature
-10º C to 40º C (14º F to 104º F)
Operating humidity
95% relative humidity
Warranty
2 years for electronics and lifter
358.65 mm
(14.12”)
157.23 mm
(6.19”)
206.25 mm
(8.12”)
127.00 mm
(5.00”)
7.26 kg
(16.00 lb)
* To prevent damage to equipment, use the input module switch on the front of the control module to select the input
voltage (115 V or 240 V) that will be used.
381.00 mm
(15.37”)