![hymer ERIBA Touring 2012 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/hymer/eriba-touring-2012/eriba-touring-2012_instruction-manual_2192958072.webp)
72
Touring - 04/11-1 - englisch (EN) - 2048869 - HYW-0102-09EN
8
Electrical system
8.3.2
Energy balance of the living area battery
The living area battery has a limited power supply only. For this reason, the
electrical appliances should not be operated without a 240 V power supply for
a longer period of time.
Below, the calculation of the maximum operating time of the currently available
battery capacity is described.
Record the daily requirement. Note the switching on times and the power
output of the devices used (see table below).
Example:
In the morning, three spotlights with 10 watts [W] each are lit in the bathroom
for 30 minutes.
Convert the power data into the required capacity in accordance with the
following formulas:
Power consumption [W] : 12 [V] = Current [A]
Current [A] x Operating time [h] = Capacity [Ah]
Example:
30 [W] : 12 [V] = 2.5 [A]
2.5 [A] x 0.5 [h] = 1.25 [Ah]
The table for a whole day could look like this:
Calculate the maximum effective energy with the following formula or
determine it with a special indicator unit:
Current capacity [Ah] : Deep discharge protection = Maximum effective
energy [Ah]
Example:
80 Ah : 1.3 (gel battery) = 61.5 Ah
Calculate the maximum operating time in accordance with the following for-
mula:
Max. effective energy [Ah] : Daily requirement [Ah] = Max. operating time
(in days)
Z
The example calculation refers to a new, optimally charged battery. The
actual effective battery capacity depends on the current charging condition
and the age of the battery. The current battery capacity can be determined
by means of special indicator units.
Appliance
Power con-
sumption [W]
Current
[A]
Operating
time [h]
Capacity
[Ah]
Balance of energy
consumption
(example)
Bathroom lighting
30
2.5
0.5
1.25
Submerged pump
42
3.5
0.1
0.35
Heater
12
1.5
3.0
4.50
Television
36
3.0
2.5
7.50
Satellite unit
36
3.0
2.5
7.50
Kitchen lighting
21
1.8
2.0
3.50
Refrigerator
2
0.2
24.0
4.00
Living area lamps
20
1.6
1.5
2.50
Average daily requirement
31.10
Содержание ERIBA Touring 2012
Страница 2: ...Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN Instruction manual...
Страница 14: ...Contents 14 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN...
Страница 16: ...16 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN Checklist before first journey of the vehicle...
Страница 20: ...20 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 1 Introduction...
Страница 38: ...38 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 3 Before the journey...
Страница 40: ...40 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 4 During the journey...
Страница 44: ...44 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 5 Pitching the caravan...
Страница 118: ...118 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 11 Care...
Страница 128: ...128 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 12 Customer service and maintenance...
Страница 138: ...138 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 13 Wheels and tyres...
Страница 148: ...148 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 15 Special equipment...
Страница 150: ...150 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 16 Technical data...
Страница 158: ...Index 158 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN...