![hymer ERIBA Touring 2012 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/hymer/eriba-touring-2012/eriba-touring-2012_instruction-manual_2192958024.webp)
24
Touring - 04/11-1 - englisch (EN) - 2048869 - HYW-0102-09EN
2
Safety
2.5
Gas system
2.5.1
General instructions
X
Before commencing the journey, when leaving the vehicle or when gas
equipment is not in use, close all gas isolator taps and the main isolator
tap on the gas bottle.
X
No appliance operated by a naked flame (e.g. heater or refrigerator) may
be in operation when filling the tank, on ferries or in the garage. Danger
of explosion!
X
Do not use appliances operated with a naked flame in closed spaces
(e.g. garages). Danger of poisoning and suffocation!
X
Only have the gas system maintained, repaired or altered by an author-
ised specialist workshop.
X
Have the gas system checked by an authorised specialist workshop
according to the national regulations before commissioning. This also
applies for not registered vehicles. For modifications to the gas system
have the gas system immediately checked by an authorised specialist
workshop.
X
The gas pressure regulator and exhaust gas pipes must also be
inspected. The gas pressure regulator has to be replaced after 10 years
at the latest. The vehicle owner is responsible for seeing that this is car-
ried out.
X
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X
Open the lifting roof before taking open sources of combustion (gas
cooker) into service.
X
Do not use the gas cooker or gas oven for heating purposes.
X
If the vehicle or gas devices are not used, close the regulator tap on the
gas bottle.
X
If there are several gas devices, each gas device must have its own gas
isolator tap. If individual gas devices are not in use, close the respective
gas isolator tap.
X
Ignition safety valves must close within 1 minute after the gas flame has
extinguished. A clicking sound is audible. Check function from time to
time.
X
The built-in gas devices are exclusively meant for use with propane or
butane gas or a mixture of both. The gas pressure regulator as well as
all built-in gas devices are designed for a gas pressure of 30 mbar.
X
Propane gas is capable of gasification up to -42 °C, whereas butane gas
gasifies at 0 °C. Below these temperatures no gas pressure is available.
Butane gas is unsuitable for use in winter.
X
Regularly inspect the gas tube fitted to the gas bottle connection for
tightness. The gas tube must not have any tears and must not be
porous. Have the gas tube replaced by an authorised specialist work-
shop no later than ten years after the manufacturing date. The operator
of the gas system must see to it that the parts are replaced.
Содержание ERIBA Touring 2012
Страница 2: ...Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN Instruction manual...
Страница 14: ...Contents 14 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN...
Страница 16: ...16 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN Checklist before first journey of the vehicle...
Страница 20: ...20 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 1 Introduction...
Страница 38: ...38 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 3 Before the journey...
Страница 40: ...40 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 4 During the journey...
Страница 44: ...44 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 5 Pitching the caravan...
Страница 118: ...118 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 11 Care...
Страница 128: ...128 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 12 Customer service and maintenance...
Страница 138: ...138 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 13 Wheels and tyres...
Страница 148: ...148 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 15 Special equipment...
Страница 150: ...150 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN 16 Technical data...
Страница 158: ...Index 158 Touring 04 11 1 englisch EN 2048869 HYW 0102 09EN...