7
Water Flow & Backflow Protection
Water Inlet
When the hot or cold-water inlet valve is open, the water flows to Water Inlet Channel 1 of the
Sidebag. From there it flows up to the Air Gap. The Air Gap 3 is between Channel 1 and 2. The water
under pressure shoots over the Air Gap. Channel 2 takes water down to the Water Softener 4.
From the Water Softener, water flows to Channel 5. Channel 5 is connected with the Sidebag 8 and
they fill simultaneously. When water reaches the top of Channel 5 (Sidebag is full) it overflows, filling
Regeneration Channel 6 and Overflow Channel 7.
Regeneration Channel 6 takes water to the Salt Reservoir. Regeneration Valve 13 controls filling the
Salt Reservoir.
Overflow Channel 7 takes water to the Membrane Sensor that activates Switch 12.
At that time the Controller opens Drain Valve 14, releasing water from Channel 5 and the Sidebag
through Channel 9 and the Chamber Inlet into the Wash Chamber.
Water Exhaust
The Drain Pump, pumps water to Channel 10. Channel 10 leads to Channel 11 that is connected to the
exhaust hose and to the drain.
Regeneration Valve
Drain Valve
Resin
Sidebag
Содержание L110W