hydratight
156
Chapter 14 Data Storage – Setup, Edit, &
View Groups
14.1 Introduction to Group (spreadsheet) format
Data is stored in the
BOLTSCOPE PRO
in a spreadsheet like format called a
GRID
. A
GRID
is simply a table of readings. In the case of the
BOLTSCOPE
PRO
they will be discussed in terms of a
GROUP
. The location in a group is
specified by giving a row and column coordinate. The rows are numbered from 1
to 99 and the columns are labeled from A to Z, then AA to ZZ giving a maximum
of 52 possible columns.
The largest grid that can be held in the
BOLTSCOPE PRO
can contain
250
bolts,
1
Unloaded length
(L-REF)
, and
51
Elongations. Multiple groups can be
created and stored until the
BOLTSCOPE PRO
’s memory is full. If the user
attempts to store a grid in the
BOLTSCOPE PRO
when the memory is full, the
BOLTSCOPE PRO
will respond with an error message indicating that the
memory is unable to store the new group.
The
MVX
can store a total of
8,000 readings
with a corresponding waveform
stored with every reading. The
Display Views
and
Quantities
can be toggled
for each and every possible option of the
BOLTSCOPE PRO
, provided that the
correct factors have been entered into the gauge and are being used. To make
this as clear as possible, the
Display Views (RF, RECT, and DIGITS)
can be
toggled with any stored measurement. Also, the
Quantities (Time, Elong,
Load, Stress, and %Strain)
can be toggle with any stored measurement.
Therefore, the data recordation of BOLTSCOPE PRO is an extremely powerful
tool for purposes of documentation.
14.2 Creating a new Group
Important Note:
This entire section is a step by step guide to successfully create
a group. The instructions must be used in the sequential order specified, as
follows: