BOLTSCOPE PRO
- Bolt Tension Monitor
151
This feature may be convenient for those users who want to have a quick
verification without having to constantly watch the display for a specific value to
appear. The alarm mode uses red and green LED’s to let the user know when
the fastener is inside the tolerance limits. The limits are also displayed on the
LCD in terms of a bar graph presentation. There are two limits, or alarm values,
that can be setup in the
BOLTSCOPE PRO
–
ALARM LO LIMIT
and
ALARM HI
LIMIT
. However, the user may choose to activate and utilize only one of the limit
values, depending on their specific application requirements. The procedures to
use the
ALARM MODE
feature are outlined below:
UTIL MENU – ALARM MODE
Toggle Alarm Status (on/off)
1) Press the
MENU
key once to activate the menu items tab. Press the
MENU
key multiple times to tab right, and the
ESC
key multiple times to
tab left, until the
UTIL
menu is highlighted and displaying the submenu
items.
2)
Use the
UP
and
DOWN
arrow keys to scroll through the sub menu items
until
ALARM STATUS
is highlighted.