Area:
The cross sectional area of the fastener being measured. Used to convert
load to stress. Set to zero if the user is not measuring the quantity in terms of
stress. This sub menu item enables the user to edit the area at anytime. Refer
to section 11.1 for further info.
Effective Length:
The length of the region of the fastener under stress (the
distance between the nut plus some amount of additional stress that occurs in
the head and nut(s) of the fastener). This sub menu item enables the user to
edit the effective length at anytime. Refer to section 11.1 for further info.
4.5 DISP (display) – Menu
View:
Selectable RF wave, RECT (rectified), and DIGITS (large digits) views.
Refer to section 12.2 for further info.
Backlight:
Selectable OFF, ON, AUTO, or INVERT back light option.
Contrast:
Adjustable display contrast for variable light conditions.
Delay:
Provides the user the ability to change where the left side of the display
window starts according to time which is convert to a length, in english or metric
units. Refer to section 12.3 for further info.
Width:
Provides the user the ability to change the overall size of the viewable
measurement area. It functions a lot like a zoom on a camera. Refer to section
12.3 for further info.
4.6 TUNE – Menu
Gain:
Increases or decreases the overall amplitude of the signal. Much like
turning the volume up or down on a stereo receiver. Refer to section 12.4 for
further info.