hydratight
130
Starting delay
The starting
DELAY
, or starting length, is the value displayed on the bottom
lower left side of the display in both
RF
and
RECT
(Rectified) views. The
DELAY
will also be represented in the
DIGITS
(Scan Bar) view, as the length. The
starting length is the minimum length that can be viewed on the display.
Note:
Once the range is set, it will remain the same for all the views
respectively.
The procedures to adjust the
Delay
are outlined below:
Adjusting the Delay using the Hot Menus
1) Press the
MEAS
key once to activate measure menu items. Press the
MEAS
key multiple times to move right and the
ESC
key multiple times
to move left, until the
DELAY
cell is highlighted.
2) Press the
UP
,
DOWN
,
LEFT
, and
RIGHT
arrow keys to scroll the
highlighted value.
3)
Alternatively
, press the
ENTER
key to display the
Digits Edit Box
.
4) Press the
UP
and
DOWN
arrow keys to scroll the highlighted value.
5) Press the
LEFT
and
RIGHT
arrow keys to scroll the digit locations.
6) Repeat steps
4 & 5
until the
DELAY
value is correctly displayed.