![Hurco AB6 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/hurco/ab6/ab6_installation-manual_2187300135.webp)
Installation Manual
2-96
Revision E
Hurco
Installing Magnet Assembly
Locate an area on the side wall of the press brake that allows mounting of
the retract sensor so the magnet, when mounted on a moving element of
the brake, is at pinch point for common height tooling.
Warning
High Voltage! To avoid potential shock hazards,
disconnect power to the AB6 power cabinet. Failure to
do so may result in serious injury.
To avoid potential injury turn off the press brake, install
the Out of Service tag, and install the lockout device.
Prevent component damage by discharging static
electricity to a ground. Follow the procedures below:
•
Before touching, adjusting, or removing a
printed circuit board (PCB), wear a wrist strap
grounded to the cabinet or enclosure ground
point.
•
If a grounding wrist strap is not available, touch
a grounded point within the enclosure each time
before touching a PCB or electronic assembly.
An example of a grounding point is the metal
cabinet’s screws.
After assembling the magnet, follow these instructions to install the retract
sensor:
1.
Disconnect power to the press brake.
2.
Hold the sensor against the side wall and the magnet
assembly against the ram or bed (whichever moves).
3.
Align them horizontally so there is a 1/4" (6 mm) gap
between the sensor and the magnet (see the Alignment and
Spacing figure).
4.
Cut the brackets to fit the particular ram to which they are
mounted.
5.
Clean the mounting surface and secure the retract sensor.
Содержание AB6
Страница 3: ...iv Revision E Hurco...
Страница 5: ...vi Revision E Hurco...
Страница 13: ...Installation Manual xiv Revision E Hurco...
Страница 39: ...Installation Manual 1 24 Revision E Hurco...