![Hurco AB6 Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/hurco/ab6/ab6_installation-manual_2187300130.webp)
Installation
Autobend 6
November, 1999
2-91
12.
Mount the other cord-grip conduit fitting into one of the 1/2"
(6 mm) holes located at the bottom of the Large AB6 power
cabinet.
13.
Route the two-conductor cable along the press brake frame to
the Large AB6 power cabinet.
Caution
Avoid routing this cable adjacent to any cables carrying electricity.
14.
Route the cable through the fitting and into the Large AB6
power cabinet.
15.
Remove excess cable leaving only 10" (254 mm) of cable
inside the cabinet.
16.
Strip back 5" (127 mm) of outer insulation, and remove the
shield.
17.
Strip back 1/4" (6 mm) of insulation from the individual
wires.
18.
Locate connector TB14 in the upper right-hand corner on the
Relay board. Refer to the figure on the following page for the
exact location of TB14.
19.
Remove the TB14 connector.
20.
Using a small screwdriver, open position #4 (labeled K4 Coil
A in the figure on the following page) and insert one of the
wires.
Important
The “TB14 Connector” section at the beginning of this section
contains instructions about opening the connection positions on the
TB14 connector.
21.
Open position #5 (labeled K4 Coil B) and insert the
remaining wire.
22.
Replace the connector into TB14.