Installation Manual
2-88
Revision E
Hurco
2.
Install a cord-grip conduit fitting in the Guifil power box
adjacent to the connection points.
3.
Route the two-conductor cable through the fitting into the
power box and up to the connection points.
Caution
Do not route the cable adjacent to any electrical cables.
4.
Route the other end of the cable to the Large AB6 power
cabinet. Do not route this cable adjacent to any electrical
cables.
5.
Route about 10" (254 mm) of the cable through the fitting
into the Large AB6 power cabinet.
6.
Strip back 2" (51 mm) of the outer insulation.
7.
Cut off the shield and dispose.
8.
Strip back 1/4" (6 mm) of insulation on each of the individual
wires.
9.
Locate the Relay board mounted inside the back of the Large
AB6 power cabinet.
10.
Locate the TB14 connector in the upper right-hand corner of
the Relay board.
11.
Remove the TB14 connector.
12.
Using a small screwdriver, open position #6 (labeled ADV)
and insert the clear wire.
13.
Open position #7 (labeled ADV RTN) and insert the black
wire.
14.
Replace the TB14 connector.
Important
The “Relay Board and TB14 Connector” sections earlier in this
chapter contain information about locating the connector and
opening the position on it.