Installation Manual – BTS3606A Cabinet Installation
Airbridge BTS3606&3606A CDMA Base Station
Chapter 5 Installing Cables
Huawei Technologies Proprietary
5-53
3)
Lead the positive cable, the negative cable, the access control and temperature
sensor cable, and the grounding cable out of the outlet at the bottom of the cabinet.
Connect them to the BTS3606A cabinet.
For positions of the outlets, see Figure 5-56.
(1) Outlet of –48 V power cable
(2) Outlet of GND cable
(3) Outlet of access control and temperature alarm cable
(4) Outlet of hot plate power cable
(5) Auxiliary outlet of –48 V power cable
(6) Auxiliary outlet of GND cable
(7) Outlet of PGND cable
Figure 5-56
Outlets of the battery cabinet
4)
Paint the wiring terminals of the access control and temperature sensor and the
air-break switch with silicon gel to make them waterproof.
5.10.4 Installing Cables between Battery Cabinet and BTS3606A Cabinet
Lead cables of the battery cabinet through its pedestal. Connect them to the basic
cabinet of BTS3606A through waterproof components at the bottom of the BTS3606A
cabinet.
Table 5-10 provides the connection positions.
Table 5-10
Connection of external cables of the storage battery
Cable name
Connection position
Positive cable GND wiring terminal inside the BTS3606A cabinet
Negative
cable
–48 V wiring terminal inside the BTS3606A cabinet
Access control
alarm cable
2-pin connector (green) of the column at the back of BTS3606A
cabinet.
The connector is bound to the column in the front of the cabinet.
Temperature
sensor cable
2-pin socket (white) from the BTS3606A power monitoring board.
The socket is bund at the bundling rack of the waterproof module
at the bottom of the cabinet.
PGND cable