Installation Manual – BTS3606A Cabinet Installation
Airbridge BTS3606&3606A CDMA Base Station
Chapter 5 Installing Cables
Huawei Technologies Proprietary
5-3
Type of cable
Description
Color
Specification
Internal connection cable of the
storage battery box
Provided by battery
suppliers
Cross-sectional
area:25 mm
2
(29.9 ft
2
)
Internal –48 V GND power cable
from the storage battery to the
fuse and internal –48 V power
cable from the fuse to the power
subrack
–48 V GND: Black
–48 V: Blue
Cross-sectional area:
25 mm
2
(29.9 ft
2
)
Internal alarm cable of the
storage-battery box
White
External diameter:
Φ
4
mm (0.08 in.)
External power cable from the
extended battery cabinet to the
basic cabinet
–48 GND: Black
–48 V: Blue
Cross-sectional area:
35 mm
2
(41.86 ft
2
)
External equipotential PGND
cable from the extended battery
cabinet to the basic cabinet
Yellow-green
Cross-sectional area:
35 mm
2
(41.86 ft
2
)
Storage
battery cable
External access alarm cable and
temperature alarm cable of the
extended battery cabinet
4-core cables
including black,
white, red, and
green cables.
The white and
green cables are
used to connect the
access control
cable.
The red and black
cables are used to
connect the
temperature sensor
cable.
–
Note:
z
This manual does not describe cables in the cabinet backplane as they are
connected before delivery.
z
For installation procedure of the feeder, see
Airbridge BTS3606&3606A CDMA
Base Station Installation Manual – Antenna & Feeder Installation
.
z
The specifications of the feeder and the jumper between the cabinet cable inlet and
the feeder depend on the antenna configured.
5.1.2 Related Concepts
This section explains the concepts of the cable inlet and cable distribution region.