4
LP- 428 REV. 9.2.14
Code for the Installation of Heat Producing Appliances
(latest version), from American Insurance Association, 85 John Street, New
York, NY 11038.
The latest version of the
National Electrical Code, NFPA No. 70
.
NOTE:
The gas manifold and controls met safe lighting and other performance criteria when the boiler underwent tests specified in
ANSI Z21.13
– latest edition.
The hydronic supply and return connections of these products are for installation in closed loop systems ONLY!
Use of this
product in any manner other than described in this manual may result in premature product failure, substantial property damage, severe
personal injury, or death. Damage or failure of this product (or the system in which it is installed) due to unauthorized use
IS NOT
COVERED BY WARRANTY
.
NOTICE
The CSD-1 ASME Code, Section CW-400 requires that hot water heating and supply boilers have a) a UL 353 temperature control
device, b) at least one (1) temperature-actuated control to shut off the fuel supply when system water reaches a preset operating
temperature, c) a high temperature limit control that prevents the water temperature from exceeding the maximum allowable
temperature by causing a safety shutdown and lockout, and d) its own sensing element and operating switch.
The temperature control system integrated into the 926 control provided with this heating appliance complies with the requirements of
CSD-1 Section CW-400 as a temperature operation control. The control monitors the temperature difference between the inlet and the
outlet sensor, which is affected by boiler water flow. If this temperature difference exceeds 55°F (typically because of low water flow or
very low heat load), the control will reduce the maximum fan speed. If the temperature difference exceeds 60°F, the control will
effectively sense there is little or no water flow or heat load and shut the boiler down. The controller will restart automatically once the
temperature difference has dropped below 55°F and the minimum off time (anti-cycle time) has expired. In addition, if the control
senses that the outlet water temperature has reached 210°F, the boiler is put into a hard lockout and requires manual reset to restart.
TABLE OF CONTENTS
PART 1
– GENERAL SAFETY INFORMATION .......................................................................................................................... 7
A. PRECAUTIONS .......................................................................................................................................................................... 7
B. GAS ............................................................................................................................................................................................ 7
C. IMPROPER COMBUSTION ....................................................................................................................................................... 7
D. WHEN SERVICING THE BOILER .............................................................................................................................................. 7
E. BOILER OPERATION ................................................................................................................................................................. 8
F. BOILER WATER ......................................................................................................................................................................... 8
G. FREEZE PROTECTION ............................................................................................................................................................. 8
PART 2
– BEFORE YOU START ................................................................................................................................................ 8
A. WHAT’S IN THE BOX ................................................................................................................................................................. 8
B. HOW BOILER OPERATES ......................................................................................................................................................... 8
C. OPTIONAL EQUIPMENT ........................................................................................................................................................... 9
PART 3
– PREPARE BOILER LOCATION ............................................................................................................................... 10
A. BEFORE LOCATING THE BOILER .......................................................................................................................................... 10
B. FLOORING ............................................................................................................................................................................... 11
C. LEVELING AND DIMENSIONS ................................................................................................................................................ 11
D. CLEARANCES FOR SERVICE ACCESS ................................................................................................................................. 12
E. EXHAUST VENT AND INTAKE PIPE ....................................................................................................................................... 13
1. DIRECT VENT INSTALLATION OF EXHAUST VENT AND INTAKE PIPE ................................................................................ 13
2. INDOOR COMBUSTION AIR INSTALLATION IN CONFINED OR UNCONFINED SPACE ....................................................... 14
Содержание MODCON1000
Страница 40: ...40 LP 428 REV 9 2 14 E GAS VALVE Figure 22 Mod Con 1000 Gas Valve ...
Страница 46: ...46 LP 428 REV 9 2 14 Figure 25 Figure 26 Cascade Resistor Plug Installation Detail ...
Страница 47: ...47 LP 428 REV 9 2 14 Figure 27 Mod Con Cascade Master and Follower Wiring ...
Страница 48: ...48 LP 428 REV 9 2 14 Figure 28 Mod Con Internal Connection Diagram LP 428 K ...
Страница 70: ...70 LP 428 REV 9 2 14 Figure 31 MOD CON 1000 External Parts Blowout ...
Страница 71: ...71 LP 428 REV 9 2 14 Figure 32 MOD CON 1700 External Parts Blowout ...
Страница 72: ...72 LP 428 REV 9 2 14 Figure 33 ...
Страница 73: ...73 LP 428 REV 9 2 14 Figure 34 LP 445 S ...
Страница 74: ...74 LP 428 REV 9 2 14 Figure 35 LP 428 V ...
Страница 75: ...75 LP 428 REV 9 2 14 Figure 36 ...
Страница 78: ...78 LP 428 REV 9 2 14 ...
Страница 79: ...79 LP 428 REV 9 2 14 ...
Страница 80: ...80 LP 428 REV 9 2 14 MAINTENANCE NOTES ...