7.
.
8.
Install the server in the rack.
9.
Connect each power cord to the server.
10.
Connect each power cord to the power source.
Use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see "
."
HPE 16GB NVDIMM option
HPE NVDIMMs are flash-backed NVDIMMs used as fast storage and are designed to eliminate smaller
storage bottlenecks. The HPE 16GB NVDIMM for HPE ProLiant Gen10 servers is ideal for smaller database
storage bottlenecks, write caching tiers, and any workload constrained by storage bottlenecks.
The HPE 16GB NVDIMM is supported on select ProLiant Gen10 servers and can support up to 12 NVDIMMs
in 2 socket servers (up to 192GB) and up to 24 NVDIMMs in 4 socket servers (up to 384GB). The HPE Smart
Storage Battery provides backup power to the memory slots allowing data to be moved from the DRAM
portion of the NVDIMM to the Flash portion for persistence during a power down event.
For more information on HPE NVDIMMs, see the Hewlett Packard Enterprise website (
Server requirements for NVDIMM support
Before installing an HPE 16GB NVDIMM in a server, make sure that the following components and software
are available:
• A supported HPE server using Intel Xeon Scalable Processors: For more information, see the NVDIMM
QuickSpecs on the Hewlett Packard Enterprise website (
• An HPE Smart Storage Battery
• A minimum of one regular DIMM: The system cannot have only NVDIMM-Ns installed.
HPE 16GB NVDIMM option
141