Drive Protection System
The Drive Protection System (DPS) is a diagnostic tool built into the hard drives that is installed in select
HP workstations. The DPS is designed to help diagnose problems that might result in unwarranted hard
drive replacement.
When HP workstations are built, each installed hard drive is tested using the DPS, and a permanent
record of key information is written onto each drive. Every time the DPS is run, test results are written
to the hard drive. The service provider can use this information to help diagnose conditions that required
you to run the DPS software.
ECC fault prediction
When the workstation encounters an excessive number of error checking and correcting (ECC) memory
errors, it displays a local alert message. This message contains detailed information about the errant
memory module, enabling you to take action before you experience noncorrectable memory errors. ECC
memory modules are standard on the HP xw4600 Workstation.
Thermal sensors
There are several thermal sensors in your HP xw4600 Workstation that regulate the workstation fans
to maintain an acceptable, efficient chassis temperature.
Dual-state power button
With ACPI enabled, the power button can function either as an on/off switch or as a button. This feature
does not completely turn off power, but instead causes the workstation to enter a low-power standby
state. This allows you to power of the wowrkstation without closing applications, and to return to the
same operational state without any data loss.
To change the power button configuration:
1.
Select
Start
, and then select
Control Panel>Power Options
.
2.
In Power Options Properties, select the
Advanced
tab.
3.
In the Power Button section, select
Hibernate
. (Hibernate must be enabled in the Hibernate
tab.)
After configuring the power button to function as a button, press the power button to put the system in
a very low power state. Press the button again to bring the system out of this very low power state to
full power state. To completely turn off all power to the system, press and hold the power button for four
seconds.
CAUTION:
Do not use the power button to power off the workstation unless the system is not
responding; turning off the power without operating system interaction could cause damage to or loss