Screen message
Probable cause
Recommended action
601—Diskette Controller Error Diskette controller circuitry or diskette
drive circuitry incorrect.
1.
Run the Computer Setup (F10) utiltiy.
2.
Verify and replace cables.
3.
Clear CMOS.
4.
Replace diskette drive.
5.
Replace the system board.
605—Diskette Drive Type
Error
Mismatch in drive type.
1.
Run the Computer Setup (F10) Utility.
2.
Disconnect any other diskette controller devices
(tape drives).
3.
Clear CMOS.
912—Computer Cover Has
Been Removed Since Last
System Start Up
N/A
No action required.
914— Coil is not Connected
Mechanism is missing or not
connected.
1.
Reconnect or replace ing mechanism.
2.
Reseat or replace ing mechanism cable.
916—Power Button Not
Connected
The power button is not connected.
Connect power button.
917—Front Audio Not
Connected
The front audio cable is not connected. Connect front audio cable.
918—Front USB Not
Connected
Front USB is not connected.
Connect front USB cable.
960—CPU Overtemp
occurred
The ambient temperature could
exceed operating limits
(maximum=95F), or there are
obstructions to airflow, including dust
buildup.
1.
Be sure you are not operating the system in an
environment that exceeds 95F.
2.
Disconnect power and open the access panel.
3.
Verify that cables are not blocking processor
heatsink fans or front fan (if installed).
4.
Verify that there is not excessive dust on major
components.
5.
If airflow is acceptable and there is not excessive
dust, the thermal sensing circuitry has failed on the
processors or on the system board. You must
replace the processors and/or the system board.
1720—SMART Hard Drive
Detect Imminent Failure
Hard drive is about to fail. (Some hard
drives have a firmware patch that fixes
erroneous error messages.)
1.
Determine if hard drive is giving correct error
message.
2.
Run the Drive Protection System test (if
applicable).
3.
Apply firmware patch (if applicable).
See
http://www.hp.com/support
.
4.
Back up contents and replace the hard drive.
1780—Disk 0 Failure
The drive is not installed correctly or
has failed.
1.
Be sure that any jumpers are set correctly, and
that power and drive cables are connected, both
to the drive and the system board.
2.
Verify that the cables are the correct cables for
your computer model. If this message persists,
your workstation might require service.
Table 6-18
POST error messages (continued)
ENWW
POST error messages 143